20 We reserve the right to make technical changes | 83055600dUK – Translation of the original instruction manual (HMD 2) | ait-deutschland GmbH
Query EventLog
NOTE
Menu entry is only displayed if customer service access is
activated.
Events that occur during operation of the heat pump and the
heating and heating and heat pump controller (e.g. change of sys-
tem settings) are logged in the EventLog.
The menu is not shown in full here.
NOTE
If 2 heat pumps are connected, note the number displayed in
the top menu row. It provides information about which heat
pump is currently addressed.
In order to change the addressed heat pump: page 11,
“Changing the addressed heat pump in submenus“
If an entry is clicked, detailed information about this event is dis-
played.
The event list displayed on the screen contains a maximum of 20
entries. The last event that occurred is at the top of the list. If there
are more than 20 entries, the oldest (= last) entry is dropped from
the list. However, it is not overwritten, but remains stored in the
database le behind it. This le can be read out via the “data log-
ger”.
Part 1 of the controller maunual, program area “Service“, sec-
tion Data logger“.
Cur. room temp. HC Current room temperature of the worst
room in the heating circuit
Targ. room temp. HC Target temperature of the worst room
in the heating circuit
UFH total MC1 Number of oor heating circuits
assigned to the mixing circuit 1
UFH open MC1 Number of open oor heating circuits
assigned to the mixing circuit 1
numb.actuat. MC1 Number of radiator drives assigned to
the mixing circuit 1
Cur. room temp. MC1 Current room temperature of the worst
room in the mixing circuit 1
Targ. room temp. MC1 Target temperature of the worst room
in the mixing circuit 1
Query InfoLog
NOTE
Menu entry is only displayed if customer service access is
activated.
Errors that occur during operation of the heat pump are stored in
a list in the InfoLog. Each error is timestamped.
The error list contains a maximum of 100 entries. The last error
that occurred is at the top of the list. If there are more than 100
entries, the oldest (= last) entry in the list is overwritten.
The menu is not shown in full here.
NOTE
If 2 heat pumps are connected, note the number displayed in
the top menu row. It provides information about which heat
pump is currently addressed.
In order to change the addressed heat pump: page 11,
“Changing the addressed heat pump in submenus“

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik Series and is the answer not in the manual?

Alpha-InnoTec Luxtronik Series Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik Series
CategoryControl Unit
LanguageEnglish

Related product manuals