RBE – room control unit
If the system has a RBE room control unit (extra-cost accessory),
this is set here:
Operating manual RBE – room control unit
Second heat generator
Here you can activate connected additional heat genera-
tors and set their parameters or deactivate connected heat
generators
NOTE
If 2 heat pumps are connected, note the number displayed in
the top menu row. It provides information about which heat
pump is currently addressed.
In order to change the addressed heat pump: page 11,
“Changing the addressed heat pump in submenus“
NOTE
The possible settings depend on the respective unit type.
If several additional heat generators are connected you
can go to their settings by using the “Rotary pushbutton”
to scroll up or down (no submenu eld may be activated
during this scrolling).
Eciency pump
The menu is not shown in full here.
Heat distrib. sys
Heat distribution system
radiator Radiator(s)
oor heat Floor heating
control heating
Control of the heating circulation
pump
Auto Automatic control
Manual Additional menu entries visible:
output heat. nom.
output heat. Min.
Nominal and minimum power of the
heating circulation pump (limitation
for ow noise) can be manually
adjusted
Output heat. max.
Maximum performance of heating
circulation pump (only with “control
heating = auto” visible and adjustable)
Control dhw
Control of the domestic hot water
charging pump
Auto Automatic control
Manual Additional menu entry visible:
output dhw.
Performance of the DHW charging
pump manually adjustable
output dhw max.
Maximum performance of dhw
charging pump (only with “Control
dhw = auto” visible and adjustable)
output cooling
Maximum performance of cooling
dT cooling
Setting the cooling temperature
dierence in K
Set bypass valve
Setting the bypass valve
Control signal UWP Current value can be read o as %
Flow is Current value can be read o as l/h
Save settings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik Series and is the answer not in the manual?

Alpha-InnoTec Luxtronik Series Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik Series
CategoryControl Unit
LanguageEnglish

Related product manuals