EasyManua.ls Logo

Alpha-InnoTec Luxtronik User Manual

Alpha-InnoTec Luxtronik
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
UK
83055400iUK – 2.1
Operating manual
Luxtronik
Heating- and Heat Pump Control
Controller part 2
Scope of delivery, Montage, Electrical connections,
Installation of sensors, Dismantling
Software update
Switching on for the first time / Commissioning
Program area “Cooling“
Program area “Service“
Appendix

Table of Contents

Other manuals for Alpha-InnoTec Luxtronik

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik and is the answer not in the manual?

Alpha-InnoTec Luxtronik Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik
CategoryController
LanguageEnglish

Summary

Important Introductory Information

Please Read First

Crucial safety and handling instructions before operating the unit.

Symbols Guide

Explains the meaning of various symbols used in the manual.

Scope of Delivery and Mounting

Scope of Delivery Details

Lists items included in the scope of supply for installed and wall controls.

Mounting Instructions

Guides for assembling and installing the control unit on the wall.

Electrical Connections

Control Unit and Motherboard Variants

Control Unit Variants

Details different models of the control unit included in the scope of supply.

Motherboard Variants

Details different motherboard types equipped in the controller.

Sensor Assembly and Installation

External Sensor Installation

Instructions for mounting and installing the external temperature sensor.

Hot Water Sensor Installation

Instructions for mounting and installing the domestic hot water sensor.

Initial Setup and Software Management

Switching On and Commissioning

Guide for initial setup and commissioning of the heat pump controller.

Software Update / Downgrade

Procedure for updating or downgrading the controller software.

Dismantling Procedures

Safety instructions and procedures for dismantling the unit.

Heat Source Fluid Selection

Startup Guide and Parameter Configuration

Startup Guide

Step-by-step guide for initial setup and configuration of the heat pump.

Fix Startup Parameters

Allows saving and resetting configuration settings made during commissioning.

System Recovery and Emergency Operation

Reset Startup Parameters

Restores system settings to those stored during initial commissioning.

Emergency Mode

Explains the emergency operating mode and its activation conditions.

Program Area: Cooling

Select Program Area

Steps to select the program area for system configuration.

Setting Cooling Mode of Operation

Setting the automatic or manual mode for the cooling function.

Cooling Temperatures and Parameters

Set Temperatures for Cooling

Adjusting temperature setpoints for cooling operation.

Set Cooling Parameters

Configuring operational parameters for the cooling function.

Cooling Operation Modes and Activation

Cooling Based on Temperature

Details how cooling is activated based on temperature settings.

Enable Active Cooling

Conditions and prerequisites for enabling the active cooling function.

Service Program Area Overview

Select Program Area

Navigating to select the desired program area.

Query Information

Retrieving various system information and status data.

Querying System Inputs and Outputs

Query Inputs Status

Displays the status of various digital inputs and their functions.

Query Outputs Status

Displays the status of various controller outputs and their functions.

Querying Time, Error, and Outage Data

Query Elapsed Times

Shows accumulated run times for different system components.

Query Error Memory

Displays stored error messages and their timestamps.

Query Operating Hours

Shows accumulated operating hours for various components.

Query Outages

Records instances of disconnections or interruptions.

Querying Facility, Heat, and BMS Data

Query Facility Status

Displays information about the heat pump type, software versions, and operation mode.

Query Heat Quantity

Shows recorded heat quantities for heating and domestic hot water.

Query BMS System Data

Displays data if the heat pump is integrated into a building management system.

Querying Smart, Log, and Inverter Data

Query Smart Settings

Displays smart settings if an individual room controller is connected.

Query InfoLog Errors

Lists errors that occurred during operation with timestamps.

Query Inverter Parameters

Displays inverter operating parameters for service purposes.

Querying Event Log and Making Settings

Query Event Log

Lists events that occurred during operation with timestamps.

Determine Data Access

Controls access levels for system settings and parameters.

Program and Temperature Settings

Calling Up Preset Programs

Instructions for accessing preset operating programs.

Determining Temperatures

Setting various temperature parameters for heating and cooling.

Hot Gas Utilisation and Priority Settings

Hot Gas Utilisation / Desuperheater

Configuration for utilising hot gas for higher temperatures.

Determining Priorities

Setting operational priorities for the heating system.

Mixing Circuits and Thermal Control

Mixing Circuit 1 Configuration

Settings for controlling mixing circuit 1, including cooling.

Thermal Control Settings

Configuration related to domestic hot water and circulation pumps.

Defrost, Pump, and Connection Settings

Defrost and Pump Options

Settings for air defrost functionality and pump optimization.

Access and Brine/Flow Settings

Managing data access and configuring brine/flow sensors.

Heating Limit and Operational Modes

Heating Limit and Parallel Operation

Settings for heating limit, parallel operation, and remote maintenance.

Pump Optimization Time

Defines the time for heating circulation pump shutdown.

System Ventilation

Pump Efficiency and System Data Backup

Efficiency Pump Settings

Configuration of circulation pump operation for optimal efficiency.

Startup Parameters and Error Memory

Managing startup parameters and backing up error logs.

Room Control and Additional Heat Generators

RBE Room Control Unit

Configuration for the RBE room control unit accessory.

Additional Heat Generator Setup

Configuration and activation of additional heat generators.

Inverter and FlexConfig Settings

Inverter Operation Control

Configuration of the inverter for compressor frequency control.

FlexConfig Functionality

Enables individual configuration of outputs on the controller board.

Silent Mode and Pump Flow Settings

Silent Mode Operation

Settings for low-noise operation of the heat pump.

Pump Flow Settings

Configuration of pump flow lead times for circulation pumps.

Smart Operation and Smart Grid

Smart Operation Mode

Configuration for smart operation via mobile devices.

Smart Grid Functionality

Utilisation of Smart Grid functionality for electricity tariff optimisation.

Smart Grid Configuration Details

Set Decrease / Increase

Adjusting heating and hot water settings based on Smart Grid signals.

Terminal Diagrams Smart Grid

Wiring diagrams for Smart Grid connections.

Screed Heating Program Setup

Screed Heating Program Overview

Details the automatic heating of screed floors with timed temperature stages.

Screen Display and Time Settings

Configuring screen language and system date/time.

Starting and Managing Screed Heating

Starting Screed Heating Program

Procedures for initiating the screed heating program.

Terminating Screed Heating and Heatpump Configuration

Manually Terminating Screed Heating

Steps to manually stop the screed heating program.

Heatpump Configuration

Configuring the heat pump based on its type and installed components.

Data Logging and Control Panel Operations

Data Logger Function

Accessing and managing logged data.

Control Panel Operations

Adjusting display contrast, web server, and remote maintenance.

Error Diagnosis and Error Messages

Technical Data and Fault Handling

Acknowledging a Fault

Procedure for acknowledging and handling fault messages.

Controller Board Flashing Codes

Interpreting the status of LEDs on the controller board.

Technical Data Overview

Specifications, connections, and electrical data for the unit.

Sensor Ranges and System Overviews

Sensor Measuring Ranges

Specifies the measuring ranges for various sensors used by the controller.

Defrost, Air Defrost, and Flow Max Overview

Provides an overview of defrost cycles, air defrost, and flow maximum parameters.

System Settings During Commissioning

Related product manuals