8 Subject to technical amendments without prior notice | 83055400iUK – 2.1 | ait-deutschland GmbH
Dimensional drawings
All dimensions in mm.
1 Fastening holes (Ø 4,3)
2 Cable gland M16 x 1,5
3 Cable gland SW 20
Hot water sensor
The domestic hot water sensor is an optional accessory and only
functionally-relevant for a separate domestic hot water tank. You
may only use domestic hot water sensors which have been ap-
proved by the manufacturer of the heat pump.
IMPORTANT
The domestic hot water tank must be lled before con-
necting the domestic hot water sensor to the heating and
heat pump regulator.
If not already prepared at the factory, mount the domestic hot
water sensor (Ø = 6 mm) on the halfway level of the domestic hot
water tank – and always above the internal heat exchanger of the
domestic hot water tank.
1 Domestic hot water connection
2 Cold water connection
3 Heat exchanger
4 Domestic hot water sensor (Ø = 6 mm)
5 Hot-water tank
ASSEMBLY AND INSTALLATION OF SENSORS
External sensor
The external sensor (protection class IP 67) is a function-critical
accessory and included in the scope of supply.
NOTE
If the external sensor is not installed or defective, the heat-
ing and heat pump regulator automatically sets the exter-
nal temperature to -5 °C. The status display of the control
unit lights up red, the screen of the control unit reports an
error.
IMPORTANT
Mount the external sensor on the north or northeast side
of buildings. The sensor must not be exposed to direct
sunlight. The cable gland must point to the base.
1. Open the housing of the external sensor and align ≥ 2 m
over the base of the fastening point.
1 Quick-release screws
2 NTC sensor element 2.2 kΩ at 25 °C
3 Cable clamps
4 Housing sealing in housing cover
2. Mark the xing holes on the xing point and drill them into
the xing point. Insert dowels and screw the housing of the
external sensor to the wall.
NOTE
Dowels and screws for fastening the external sensor are
not included in the scope of supply.
3. Loosen cable gland and lead a 2-wire cabel (Ø 5- 9,5mm, cross
section ≤ 1.5 mm² per wire, cable length ≤50 m) through the
cable gland into the housing.
4. Fit the cable wires with wire end sleeves, place them on the ca-
ble clamps of the external sensor and tighten them with a torque
of 0.5 Nm.
5. Tighten cable glands with a torque of 2.5 Nm and close the
housing of the external sensor. Ensure that the housing seal
and the sealing surfaces are clean and that the housing seal is in
the correct position.
IMPORTANT
No moisture may be trapped in the housing. If necessary,
completely dry the inside of the housing before mounting
the housing cover.
Ensure that the tightness of the housing is guaranteed by
mounting it tension-free and that no water can penetrate
the housing of the external sensor at any time (for instance
during the construction phase).

Table of Contents

Other manuals for Alpha-InnoTec Luxtronik

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik and is the answer not in the manual?

Alpha-InnoTec Luxtronik Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik
CategoryController
LanguageEnglish

Related product manuals