26 We reserve the right to make technical changes | 83055600dUK – Translation of the original instruction manual (HMD 2) | ait-deutschland GmbH
Comp-Heater
Compressor heating
Yes Compressor heating activated
No Compressor heating deactivated
The compressor heating will be detected and regulated
automatically – insofar as present in the device. The setting
here is used for manual control during servicing.
Cooling
with CP Additional circulation pump runs
during cooling operation
wo. CP Additional circulation pump does not
run during cooling operation
Scroll all the way down,
save the settings.
pump optim. Time
If the pump optimisation is switched on ( Pump opt.=
Yes), the time be dened, according to which the heating
circulation pumps are switched o.
If the heat pump is o during this time because there is
no need for heating, the pump will loop - 30 minutes o, 5
minutes on, until there is a further heating requirement.
time pump ow ZUP
Feed-time for the additional circulation
pump
min defrost cycle
Defrost cycle time, minimum
timebetween two defrost processes
Take the time to be set from the instructions for use for the
respective L/W appliance.
time 2.CP short
Shortening second compressor stage
Time before the second compressor stage cuts in. If the
dierence between the return ow set and actual values
is greater than the setting “Hysteresis 2.CP short”, then the
second compressor stage cuts in after this time.
NOTE
A compressor may not switch on in more than three times
per hour. If this gure has already been reached, cutting in
is postponed.
TDI Message Thermal disinfection signal
Yes see error number 759
page 35, Error number 759
No fault signal/message does not arrive
release 2hg Release second heat generator
Time until the second heat generator is switched on
aux. heat. hot water
Hot water reheating
No Hot water reheating function
deactivated (in the factory)
Yes Activated, the required hot water value
becomes the hot water target value
Part 1 of the controller manual, program area„Domestic Hot
Water“, section “Hot water reheating“
aux.serv.water max.
maximum time period for hot water
reheating
maximum time period, during which the hot water should
be reheated. If this time period is exceeded the hot water
reheating is cancelled.
high pressure limit
Switch-o value high pressure (sensor)
low pressure limit
Switch-o value low pressure (sensor)
power 2hg
Power output of the electric heating
element (=second heat generator)
smart grid
No Smart Grid function switched o
Yes Smart Grid function switched on
page 30, “Smart Grid“
setting mc 1
Mixing circuit 1 speed
fast fast control speed
medium average control speed
slow slow control speed