22
Device designation
Heat pump type Brine/Water ı Air/Water ı Water/Water relevant ı not relevant
Installation location Indoors ı Outdoors relevant ı not relevant
Conformity CE
Power data Heating power/COP at
B0/W35 Standard point as per EN255
2 Compressors
1 Compressor
kW ı
kW ı
B0/W50 Standard point as per EN255
2 Compressors
1 Compressor
kW ı
kW ı
B-5/W35 Standard point as per EN255
2 Compressors
1 Compressor
kW ı
kW ı
B-0/W45 Standard point as per EN14511
2 Compressors
1 Compressor
kW ı
kW ı
Operating limits Heat circuit °C
Heat source °C
Additional operating points
Noise Sound pressure level at 1m gap around the machine averaged (in free field) dB(A)
Sound power level as per EN12102 dB
Heat source Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump p ı Volumetric flow bar ı l/h
Recommended brine circulating pump
Total compression of the recommended pump at nominal brine volumetric flow bar ı l/h
Antifreeze Monoethylene glycol
Minimum concentration ı frostproof to % ı °C
Heat circuit Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump p ı Volumetric flow bar ı l/h
Free compression of heat pump p ı Volumetric flow bar ı l/h
Temperature spread for B0/W35 K
General device data Earth (see dimensional diagram for the size indicated) Size
Total weight kg
Extra weight of construction unit 1 kg
Extra weight of construction unit 2 kg
Connections Heat circuit
Heat source
Refrigerant Refrigerant type ı Filling capacity ı kg
Electrics Voltage code ı All-pole circuit breaker for pump *) ı A
Voltage code ı Control voltage circuit breaker *) ı A
Voltage code ı Electrical heating element circuit breaker *) ı A
Heat pump Effective power consumption in the normal point B0/W35 as per EN255: Power consumption ı Current consumption ı cosφ kW ı A ı
Maximum machine current within the operating limits A
Starting current: direct ı with slow-starter A ı A
Protection type IP
Power of electrical heating element 3 ı 2 ı 1-phase kW ı kW ı kW
Components Circulating pump for heat circuit at nominal throughput: Power consumption ı Current consumption kW ı A
Circulating pump for heat source at nominal throughput: Power consumption ı Current consumption kW ı A
Setting range for motor protection switch of heat source circulating pump A
Passive cooling function Data only for devices with ID K: Cooling power at nominal volumetric ow rates (15 °C heat source, 25 °C hot water) kW
Safety devices Safety assembly for heat circuit ı Safety assembly for heat source in scope of supply: yes no
Heating and heat pump control in scope of supply: yes no
Electronic soft-starter integrated: yes no
Expansion vessels Heat source: Scope of supply ı Volume ı Supply pressure yes no ı l ı bar
Heat circuit: Scope of supply ı Volume ı Supply pressure yes no ı l ı bar
Overflow valve integrated: yes no
Vibration isolation Heat circuit ı Heat source in scope of supply: yes no
UK813198a
*) Observe local regulations n.n. = cannot be demonstrated
We reserve the right to make technical changes.
UK830509/200114 © Alpha-InnoTec GmbH
Technical Data/Scope of Supply

Table of Contents