3.3 Viewing Operating Mode Parameters
The flow diagram below shows the viewable parameters that are scrolled through as the
program key (P) is pressed:
PR
ALM 1
ALM 2
Model DS200 0 DEWPOINT METER
dew TEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETER
dewTEC
DEW POINT
PR
ALM 1
ALM 2
Model DS200 0 DEWPOINT METERdew TEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETERdewTEC
Maximum
(H igh) value
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT METE RdewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT ME TERdewTEC
Minimum
(L o w ) value
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT METE RdewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT ME TERdewTEC
Alarm 1
Elapsed Time
PRESS PRESS
PRESS PRESS
PRESS PRESS
PRESS PRESS
PR
ALM 1
ALM 2
Model DS2 000 DEWPOINT METERdewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETERdewTEC
Alarm 2
value
PR
ALM 1
ALM 2
Model DS2 000 DEWPOINT METER
dewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETER
dewTEC
PR
ALM 1
ALM 2
Model DS2 000 DEWPOINT METERdewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETERdewTEC
Alarm 1
value
PR
ALM 1
ALM 2
Model DS2 000 DEWPOINT METER
dewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETER
dewTEC
Alarm 1 H ysterisis
value
PR
ALM 1
ALM 2
Model DS2 000 DEWPOINT METERdewTEC
PR
ALM 1
ALM 2
Model DS2000 DEWPOINT M ETERdewTEC
Total
PRESS PRESS
PRESS PRESS
PRESS PRESS
PRESS PRESS
PRESS PRESS
Alarm 2 H ysterisis
value
NOTE
: These displays
will not appear if the
Help
function is disabled
Initial Display at Start Up. Displays your process
Dewpoint.
Maximum (High) Dewpoint since last reset. To reset,
press the (R) key when displayed.
Minimum (Lo) Dewpoint since last reset. To reset, press
the (R) key when displayed.
Accumulated time that Alarm 1 has been active since last
reset. This display format is in mm.ss up to 99 minutes
and 59 seconds, after which the format changes to
mmm.s. To reset, press the (R) key when displayed.
Dewpoint at and above which (Process High Alarm) or at
and below which (Process Low Alarm) Alarm 1 is active.
To set press (
) when displayed and follow the
instructions given in paragraph 3.4.
Defines the width of the hysterisis band in dewpoint
applied on the ‘safe’ side of the Alarm 1 level. Set in the
same manner as Alarm value.
Dewpoint at and above which (Process High Alarm) or at
and below which (Process Low Alarm) Alarm 2 is active.
To set press (
) when displayed and follow the
instructions given in paragraph 3.4.
Defines the width of the hysterisis band in dewpoint
applied on the ‘safe’ side of the Alarm 2 level. Set in the
same manner as Alarm value.
Total value based upon integration of the input signal
using the time base set in the hygrometer settings.
Automatic display change if there
is no key activity after 3 seconds
Display change due to key activity
dewTEC DS2000 User’s Manual Page 10