TROUBLESHOOTING
De lux e Control Cook & Hold ▪ Service Manu al ▪ MN -46 712 ▪ Rev 01 ▪ 11 /20
55
Replace CB. Does the J11 plug continue outputting
12VDC to the SSR while the registered temperature is
above the set temperature?
No
Measure and monitor current draw to heat cable
wraps to ensure oven is now cycling at the set
temperature.
Yes
Replace IB. Does the J11 plug continue outputting
12VDC to the SSR while the registered temperature is
above the set temperature?
No
Measure and monitor current draw to heat cable
wraps to ensure the oven is now cycling at the
set temperature.