767-SK, 1767-SK INSTALLATION/OPERATION/SERVICE MANUAL Pg. 9.
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
E
lectrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the
O
FF
position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
E L E C T R I C A L C O N N E C T I O N
I N S T A L L A T I O N
E L E C T R I C A L - 7 6 7 - S K
VOLTAGE PHASE CYCLE/HZ AMPS kW CORD & PLUG
120 1 60 16.8 2.1 NEMA 5-20P
20A - 125V PLUG
208-240 (UL)1 60 15.4 3.2
NO CORD
at 208 1 60 15.4 3.2
&
PLUG
at 240 1 60 12.2 2.9
230 1 50 11.3 2.6
CEE 7/7
220-230V
PLUG
E L E C T R I C A L - 1 7 6 7 - S K
VOLTAGE PHASE CYCLE/ HZ AMPS kW CORD & PLUG
208-240 (UL)1 60 30.8 6.4
NO CORD
at 208 1 60 30.9 6.4
& PLUG
at 240 1 60 24.4 5.9
230 1 50 24.0 5.5
NO CORD
& PLUG
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.