MN-28657 (Rev 1) 03/15 • AR-7E Rotisserie • 3
INSTALLATION
SITE INSTALLATION
In order to maintain established
National Sanitation Foundation
standards, all counter- mounted
models must be sealed to the
counter with a R.T.V. or silastic
meeting N.S.F. requirements or
have 6" (152mm) unobstructed
clearance at the back and sides
of the unit.
1. The appliance must
be installed on a non-
combustible, level surface.
2. DO NOT install this appliance in any area where it
may be affected by any adverse conditions such as
steam, grease, dripping water, high temperatures, or
any other severely adverse conditions.
3. For both safety and convenience, the rotisserie must
be installed in a location to provide easy access
to the controls and should be positioned at a safe
and convenient height to provide easy loading and
unloading of hot products.
4. This appliance must be kept free and clear of
any obstructions blocking access for maintenance
or service.
5. A rotisserie can be stacked with another rotisserie
oven or stacked on top of a matching holding
cabinet. Complete stacking instructions are
located in this manual.
®
LEVELING
Level the appliance from side-to-side and
front-to-back with the use of a spirit level.
We recommend checking the level periodically
to make certain the floor has not shifted nor the
appliance moved.
NOTE: Failure to properly level this appliance
can cause improper function.
Improper installation, alteration,
adjustment, service, cleaning, or
maintenance could result in property
damage, severe injury, or death.
Read the installation, operating and
maintenance instructions thoroughly
before installing, servicing, or
operating this equipment.
DO NOT store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance. Failure to observe this
precaution may result in a fire,
explosion or personal injury.
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN
IN OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
Appliance and accessories may be
heavy. To prevent personal injury, use
caution when moving or leveling this
appliance or handling accessories.
MINIMUM CLEARANCE REQUIREMENTS
A 6" (152mm) minimum clearance must be allowed at the
back and both sides of the unit. Warranty will become
null and void if these directions are not followed.
A number of adjustments are associated with initial
installation and start-up. It is important that these
adjustments be conducted by a qualified service
technician. Installation and start-up adjustments
are the responsibility of the dealer or user. These
adjustments include but are not limited to thermostat
calibration, door adjustment, leveling, electrical
hook-up and installation of optional casters or legs.
SOUND PRESSURE MEASUREMENT
Microphone
position
Sound pressure level dBA
Without hood
system operating
With hood system
operating
Front 69 71
Right Side 64.3 67
Left Side 64.3 69
Rear 64.7 68