OPERATING INSTRUCTIONS
COMBITHERM® CT PROFORMANCE™ SERIES • STEP-BY-STEP PROCEDURES • MN-35948 • 33.
Grease Filter
(FI-25867):
Cleaning frequency should be based on oven
usage with a maximum of two weeks between
cleaning if the oven is used for non-grease laden
products or steam applications only. Grease
laden products require cleaning frequency of at
least once a week.
Remove the grease filter by pulling it straight
out of the housing. Place the filter in the
dishwasher or wash separately by placing in
hot, soapy water until all grease and particles
have been removed. Rinse thoroughly. Allow
the filter to air dry before reinstalling.
To replace the grease filter, the air flow arrow on
the filter casing should be pointing toward the
hood fan.
Charcoal Filter
(Class I - FI-36620):
The charcoal filter should be inspected for
contaminant's on a regular basis. Replacement
must be made at a minimum of three month
intervals — more often if heavy contaminant's
are visible or if the filter no longer controls
odors.
To remove the filter, pull and slide out while
holding the bottom housing. When replacing
the filter, make certain the air flow arrow(s)
point toward the hood fan, and that the filter
is replaced in the three-sided metal frame
provided with the hood.
COMBIHOOD PLUS™ VENTLESS HOOD OPTION
NOTE:
A pressure switch is used to detect when the airflow
through the charcoal filter is reduced by 25% -
indicating a possible blockage. This will generate an
E101 error message on the oven control display. The
filters will need to cleaned or replaced.
If the filters are not seated properly, an error code E102
will appear on the oven control display at the end of a
cooking cycle.
Quarter Turn Release
(access to filters)
Quarter Turn Release
(access to filters)