SCHEMATICS
Co nv erg e® ▪ Se rvice Ma nual ▪ MN-47 241 ▪ Rev 1 ▪ 6 /22
105
SCHEME
REVISION
/
3
77777
11
11
12
11
10
9
8
7
6
5
4
3
2
1
LEGEND
A1 = COIL INPUT (+)
A2 = COIL INPUT(-)
B1 = H2O PROBE LOW
B2 = H2O PROBE HIGH
B3 = WATER PROBE
B4 = BOILER PROBE
B5 = STEAM BY-PASS PROBE
B10 = FOOD PROBE
B11 = MULTI-POINT PROBE
BLWR = GAS CONV BLOWER
C/B = CIRCUIT BREAKER
CAB = CABLE
CB = CONTROL BOARD
CC = CATALYTIC CONVERTER
CH = CONV HEATER
CV = CONVECTION
E1 = BOILER ELEMENT SET
E2 = BOILER ELEMENT SET
E3 = BOILER ELEMENT SET
E41 = CONV ELEMENT SET K3 = BOILER CONTACTOR
N7 = HIGH LIMIT
E42 = CONV ELEMENT SET
E43 = CONV ELEMENT SET
EL = ELEMENT
FA = FAN
FE = BOILER FUSE
FST = CONV FUSE
FSW = FILTER SWITCH
FT = X-CAP FILTER
FTT = COOLING FAN THERMOSTAT
FU = FUSE
G. PUMP = GREASE PUMP
GND = GROUNDING
GU = HALOGEN LIGHT
HIS = HOT SURFACE IGNITOR
IB = INTERFACE BOARD
IM = IGNITION MODULE
K1 = BOILER CONTACTOR
K2 = BOILER CONTACTOR
K40 = CONV CONTACTOR
K41 = CONV CONTACTOR
K42 = CONV CONTACTOR
K43 = CONV CONTACTOR
K45 = CONV CONTACTOR
K50 = MOTOR CONTACTOR LOW
K51 = MOTOR CONTACTOR LOW
K60 = MOTOR CONTACTOR LOW
K61 = MOTOR CONTACTOR LOW
S7 = REED SWITCH
K78 = MASTER CONTACTOR
LED = LIGHT EMITTING DIODE
LF = LINE FILTER
LQ. PUMP = LIQUID PUMP
LWR = LOWER
LWS = STEAM RELIEVE VALVES
N8 = BOILER TEMP PROBE
N9 = HIGH LIMIT
N10 = HIGH LIMIT
NC X = NO CONNECTION
NC = NORMAL CLOSE
NO = NORMAL OPEN
OB = OPTION BOARD
PS = POWER SUPPLY
PSW = PRESSURE SWITCH
RLY = RELAY
RV = STEAM RELIEF VALVE
K77 = MASTER CONTACTOR
SMK = SMOKER
SMO = STEAM MOTOR
SPI = SPARK IGNITOR
SSR = SOLID STATE RELAY
SV = STEAM VALVE
SW = SWITCH
MO = MOTOR
N6 = CAVITY PROBE
--- = ----------
TM = TERMINAL
TB = TERMINAL BLOCK
TX = TRANSFORMER
VFD = VARIABLE FRENCY DRIVE
Y1 = STEAM VALVE
Y2 = MIXED WATER VALVE
Y3 = CLEAN VALVE
Y4 = CLEAN PUMP
Y5 = HAND SHOWER
--- = ----------
--- = ----------
--- = ----------
--- = ----------
UPP = UPPER