OPERATION
Co nv erg e® ▪ Se rvice Ma nual ▪ MN-47 241 ▪ Rev 1 ▪ 6 /22
17
How to Calibrate the Temperature Probe
Before you begin Make sure:
▪ The oven is on, but not in cooking or holding mode.
▪ You have a thermometer.
▪ You have a container filled with ice and water.
Procedure To calibrate the probe, do the following.
Step Action
1. Place the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2. Touch the menu icon a. The control displays the menu screen.
3. Touch the Settings icon b. The control displays the General Settings screen.
Continued on next page
CT-TS-013849
a
CT-TS-013852
b