MAINTENANCE
Co nv erg e® Se rvice Ma nual MN-47 241 Rev 1 6/22
70
Continued from previous page
Inspect all drain hoses and clamps.
Inspect all steam water injection lines and clamps for leaks or potential issues.
Inspect wiring to heating elements. Re-tighten or secure as needed. Record the
amp draw.
Inspect wiring to the steam element. Re-tighten or secure as needed. Record the
amp draw.
Inspect the cleaning system pump and hoses for leaks and proper operation.
Check operation of all electrical cooling fans.
Test steam injection solenoid.
Test condensate solenoid.
Check all electrical connections are properly connected and secure to the
boards.
Check door hinges and handles. Tighten, secure, or adjust as needed.
Check door gaskets for damage and seal.
Run each chamber in convection mode and test operation.
Run each chamber in steam mode and test operation.
For ovens shipped to New Zealand or Australia, inspect the back flow preventer
check valve per AS/NZ3500.1 and AS/NZ3500.2