MN-38954 • Rev 0 • 04/17 • Quickchillers 31
Operation
Service Mode
ID: 0A:51:00:00:00:00 2016/06/10
IB: 02.01 15:33:37
CB: 0.00
PCB: 0ºF
N6: 0ºF
P1 0ºF
P2 0ºF
P3 0ºF
Coil 0ºF
SW1
DEF Timeout: 0:00:00
SL FA
DRH
DEF
Relay Force Buttons
NOTICE: For use by qualified
personell only.
SL = Solenoid
FA = Fan
DEF = Defroster
DRH = Drain Heater
ID: 0A:51:00:00:00:00 2016/06/10
IB: 02.01 15:33:37
CB: 0.00
PCB: 0ºF
N6: 84ºF
P1 43ºF
P2 72ºF
P3 85ºF
Coil -24ºF
SW1
DEF Timeout: 1:22:15
SL FA
DRH
DEF
Serial number of
board combination
Interface Board Version
Control Board Version
Control Board Temperature
Cavity Temperature
Probe 1 Temperature
Probe 2 Temperature
Probe 3 Temperature
Coil Temperature
State of Switch 1
Time until Defrost
Current Date
Current Time