MAINTENANCE
Ve ctor  F®  Se ries      ▪    S ervice   Ma nual     ▪     M N- 46 89 5    ▪    R ev  1   ▪   7/ 20
52
Continued from previous page
▪ Record the software versions and update if necessary.
▪ Record the amp draw of all elements on the service screen individually.
▪ Record the incoming supply line voltage.
▪ Test each chamber fan for correct operation.
▪ Test each chamber heater for correct operation.
▪ Test the chamber lights.