TESTING
Ve ctor F® Se ries S ervice Ma nual M N- 46 89 5 R ev 1 7/ 20
66
How to Test the Probe
Before you begin Make sure you have:
Multimeter
Container of ice water
Procedure To test the probe, do the following.
Step Action
1. Set the multimeter a to ohms.
2. Insert the probe b into a container of ice water.
Continued on next page
NOTE: Stir the water with the probe to ensure an
accurate measurement.
VMC-TS-003717
a
VMC-TS-003717
b