TESTING
Ve ct or F ®  Se ries      ▪    S ervice   Man ual     ▪     MN -4 6 895     ▪    R ev  1     ▪    7/ 20
67
Continued from previous page
3. Insert the meter leads c into the probe connector. The measurement 
should be between 99 and 101 ohms at 32°F (0°C).
Result The probe has now been tested.
 
NOTE: If the measurement is not between 99 and 101 
ohms, replace the faulty probe.