TESTING
Ve ctor F® Se ries ▪ S ervice Ma nual ▪ M N- 46 89 5 ▪ R ev 1 ▪ 7/ 20
64
Continued from previous page
6. Touch the chamber g you want to test. A check mark indicates that
chamber’s heater is on.
7. Measure the amp draw while the heater is on. The amperage draw of a
functioning heater element is 7–9 amps.
The heater will automatically stop after one minute of operation. See topic
The Chambers will not Heat if the heaters do not turn on.
Continued on next page
WARNING: Electric shock hazard.
Use caution when testing line voltage.
Touch a chamber to turn its
heater ON or OFF
1
2
3
4