10. Open the D valve (photo D-5.1) to fill the return line, to push antifreeze out and eventually
the bleach out, let it run for at least 1 minute.
11. After 4 hours, repeat t steps 1 to 10 without adding bleach in order to drain bleach from
the plumbing system and complete a final potable water fill up. To better rinse the system
repeat steps 1 to 10 without adding bleach.
12. To use your Aquago water heater, open the panel, tilt the lever open, reinstall the filter
cartridge, tilt the lever back to close, switch the water heater “ON” on the outside switch
and close panel.
13. Open the bypass valves A and B (photo D-5.2 and D-5.3)) to horizontal position.
14. Open the E valve (photo D-5.4) of the return line.
15. Open the D valve (photo D-5.1) and let the water run on the ground under the ALTO during
about 2 minutes to allow the filling up of the water heater and of the return line.
16. You can now turn your water heater on and use it.
17. Dump grey and black water tanks and fill the potable water tank up. You are now ready
for the camping season.
Come winter, see WINTERIZING POTABLE WATER SYSTEM WITH TRUMA AQUAGO COMFORT
PLUS INSTANT WATER HEATER
IMPORTANT: Make sure water heater is full before turning it on. It is full when water has
been running for more than three (3) minutes using hot water tap.