4 www.amana-hac.com SS-AHVE* (115V)
SS-AHVE* (115V) www.amana-hac.com 5
Dimensions
AVPEC_DIMENSIONS
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
F
C
D
E
B
A
F
C
D
E
B
SC
CC
1-13/16" (4.60 cm)
1-13/16" (4.60 cm)F
INLET
(FRONT VIEW)
H
G
E
D
2-11/16" (6.83 cm)
1-11/16" (4.29 cm)
10-3/32" (25.88 cm)
5/8" (1.59 cm) 5/8" (1.59 cm)B
C
K J
1-15/16" (4.92 cm)
3-11/16" (9.37 cm)
7-1/8" (18.1 cm)
1" (25.4 cm) 17/3219.5" (49.53 cm)
INLET
(RIGHT SIDE VIEW)
A
1-25/32" (4.52 cm)
1-13/32" (3.57 cm)
3-1/16" (7.78 cm)
5-5/32" (13.10 cm)
7-17/32" (19.13 cm)
9-5/32" (23.26 cm) 11-7/32" (28.50 cm)
21/32 (1.67 cm)
21" (55.88 cm)
1-23/32" (4.13 cm)
1-1/2" (11.43 cm)
1-11/32" (3.33 cm)
1-5/8" (4.13 cm)
2-31/32" (7.46 cm)
3-1/32" (7.70 cm)
3-25/32" (9.60 cm)
SCALE: NTS
SHEET: 1 OF 1
DWG.
NO.
AVPEC_DIMENSIONS
SPECIAL CHARACTERISTICS: (REFER MSP 822-01 FOR DETAILS)
= CRITICAL CHARACTERISTIC REQUIRES AN INITIAL CPK OF 1.33 AND USE OF STATISTICAL PROCESS CONTROL.
= SIGNIFICANT CHARACTERISTIC REQUIRES AN INITIAL CPK OF 1.00 AND USE OF STATISTICAL PROCESS CONTROL.
INABILITY TO MEET THE REQUIRED INITIAL CPK VALUE WILL REQUIRE 100% INSPECTION.
CONFIDENTIAL PROPERTY OF GOODMAN MANUFACTURING COMPANY, L.P. OR ITS AFFILIATES NOT TO BE DISCLOSED TO
OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAD,
ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT
VERTICAL DRAIN
PORT DEATIL
SEE VERTICAL
DRAIN PORT DETAIL
SEE HORIZONTAL
DRAIN PORT DETAIL
SUCTION TUBE
LIQUID LINE
INLET TUBE
HORIZANTAL DRAIN
PORT DEATIL
Model A B C D E F G H I J K
AHVE24BP0400 45 16⅜ 17½ 15⅝ 12 14⅛ 9 12¾ 3¹³₁₆ 2⅞ 2 15/16
AHVE36CP0400 53⁷₁₆ 19⅞ 21 21¹³₁₆ 18⅝ 17¹¹₁₆ 10¹³₁₆ 6¹³₁₆ 3¹³₁₆ 2⅞ 2 15/16
AHVE42CP0400 53⁷₁₆ 19⅞ 21 21¹³₁₆ 18⅝ 17¹¹₁₆ 10¹³₁₆ 6¹³₁₆ 3¹³₁₆ 2⅞ 2 15/16
AHVE48DP0400 53⁷₁₆ 23⁵₁₆ 24½ 21½ 18⁵₁₆ 21³₁₆ 12⅝ 6⅞ 4 3 3 3/32
AHVE60DP0400 58 23⁵₁₆ 24½ 26⅛ 22⅞ 21³₁₆ 12⁵₁₆ 13¼ 4 3 3 3/32
Rated indoor airflow rate [SCFM]
Static pressure [wc]
ID unit OD unit 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
AHVE24BP0400
ASZS601810A*/GSZS601810A* 610 610 610 610 610 610 610 610 610
ASZS602410A*/GSZS602410A* 800 800 800 800 800 800 800 800
800
AHVE36CP0400
ASZS60241EA* 800 800 800 800 800 800 800 800
800
ASZS603010A*/GSZS603010A* 1010 1010 1010 1010 1010 1010 1010 1010 1010
ASZS603610* / GSZS603610* 1260 1260 1260 1260 1260 1260 1260 1260 1260
AHVE42CP0400
ASZS603610A*/GSZS603610A*/
ASZS60361EA*
1260 1260 1260 1260 1260 1260 1260 1260 1260
ASZS604210A*/GSZS604210A* 1320 1320 1320 1320 1320 1320 1320 1320 1320
AHVE48DP0400
ASZS60361EA* 1260 1260 1260 1260 1260 1260 1260 1260 1260
ASZS604210A*/GSZS604210A* 1320 1320 1320 1320 1320 1320 1320 1320 1320
ASZS604810A*/GSZS604810A* 1380 1380 1380 1380 1380 1380 1380 1380 1380
AHVE60DP0400
ASZS60361EA* 1260 1260 1260 1260 1260 1260 1260 1260 1260
ASZS604210A*/ASZS60421EA*/
GSZS604210A*
1320 1320 1320 1320 1320 1320 1320 1320 1320
ASZS604810A*/ASZS60481EA*/
GSZS604810A*
1380 1380 1380 1380 1380 1380 1380 1380 1380
ASZS606010A*/GSZS606010A* 1640 1640 1640 1640 1640 1640 1640 1640 1640
AHVE24; AHVE36; AHVE42
AHVE24; AHVE36; AHVE42
8
7
6
5
4
2
13
E
D
B
A
C
CONFIDENTIAL PROPERTY OF GOODMAN MANUFACTURING COMPANY, L.P. OR ITS AFFILIATES NOT TO BE DISCLOSED TO
OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND,
ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABL E SECTION OF GOODMAN MSP
860-01 WORKMANSHIP STANDARD.
SPECIAL CHARACTERISTICS: (REFER MSP 822-01 FOR DETAILS)
=
CRITICAL CHARACTERISTIC REQUIRES AN INITIAL CPK OF 1.33 AND USE OF STATISTICAL PROCESS CONTROL.
=
SIGNIFICANT CHARACTERISTIC REQUIRES AN INITIAL CPK OF 1.00 AND USE OF STATISTICAL PROCESS CONTROL.
INABILITY TO MEET THE REQUIRED INITIAL CPK VALUE WILL REQUIRE 100% INSPECTION.
SC
CC
INTERFERENCE DOCUMENT
DATE: 1-6-22
ENG: KM
DWN BY: HP
DO NOT SCALE DRAWING
DV48FECD14_AMST_STUDY_1
1
REV
CHK BY: VM
SHT 4 OF 4
GOODMAN MANUFACTURING COMPANY, L.P.
TOLERANCES UNLESS
OTHERWISE NOTED
ANGLES ± 1.
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
9
8
7
6
5
4
2
1
39
F
E
D
B
A
C
F
B
DETAIL B
I
J
K
1.5/8(4.13 cm)
*The chart is for informaon only. For sasfactory operaon, external stac pressure must not exceed 0.5 wc.
*Unit may provide dierent SCFM during electrical heater operaon. See IO manual for the airow rate.

Other manuals for Amana AHVE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amana AHVE Series and is the answer not in the manual?

Amana AHVE Series Specifications

General IconGeneral
BrandAmana
ModelAHVE Series
CategoryAir Handlers
LanguageEnglish

Related product manuals