4 www.amana-hac.com SS-AHVE* (115V)
SS-AHVE* (115V) www.amana-hac.com 5
A B C D E F G H J
AHVE24BP0400 45 16⅜ 17½ 15⅝ 12 14⅛ 9 12¾ 3¹³⁄₁₆ 2⅞ 2 15/16
AHVE36CP0400 53⁷⁄₁₆ 19⅞ 21 21¹³⁄₁₆ 18⅝ 17¹¹⁄₁₆ 10¹³⁄₁₆ 6¹³⁄₁₆ 3¹³⁄₁₆ 2⅞ 2 15/16
AHVE42CP0400 53⁷⁄₁₆ 19⅞ 21 21¹³⁄₁₆ 18⅝ 17¹¹⁄₁₆ 10¹³⁄₁₆ 6¹³⁄₁₆ 3¹³⁄₁₆ 2⅞ 2 15/16
AHVE48DP0400 53⁷⁄₁₆ 23⁵⁄₁₆ 24½ 21½ 18⁵⁄₁₆ 21³⁄₁₆ 12⅝ 6⅞ 4 3 3 3/32
AHVE60DP0400 58 23⁵⁄₁₆ 24½ 26⅛ 22⅞ 21³⁄₁₆ 12⁵⁄₁₆ 13¼ 4 3 3 3/32
Wiring Diagram
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
4
3
6
5 9
8
7
10
11 12
BK
RD
BK
RD
BL
RD
PU
YL
RD BK
GROUND LUG
24VAC
TB5
TB4
INSTALLI NG
AUX ALARM
(ALARM)
(SEE NOTE 7)
~
~
~
~
~
~
24VAC
COM COM
120
VAC
120
VAC
TR2 TR1
FAN
MOTOR
21
GY
BL
BK
RD
ECM MOTOR
BK
RD
FPL
MPL
INTEGRATED CONTROL:
COMPONENT CODES:
TL
F1U, F2U
TR
THERMAL LIMIT
TRANSFORMER
FUSE LINK
NOTES:
1. MANUFACTURER'S SPECIFIED REPLACEMENT
PARTS MUST BE USED WHEN SERVICING.
2. IF ANY OF THE ORIGINAL WIRES AS
SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED
WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY.
3. UNIT MUST BE PERMANENTLY GROUNDED
AND CONFORMED TO N.E.C AND LOCAL CODES.
4. TO RECALL THE LAST 6 FAULTS, MOST
RECENT TO LEAST RECENT, DEPRESS
FAULT RECALL BUTTON FOR MORE THAN 2
SECONDS WHILE IN STANDBY (NO THERMOSTAT
INPUTS)
5. RED STATUS LED PROVIDES NETWORK STATUS.
GREEN RX LED INDICATES NETWORK TRAFFIC.
USE LEARN BUTTON TO RESET NETWORK.
6. THE POSITION OF SELECTOR SWITCHES
(DS1 - DS6) INDICATE FACTORY SETTING.
7. REMOVE SHORT RED WIRE AND PUT AUX ALARM
SWITCH WHEN INSTALLING AUX ALARM SWITCH.
8. HEATER KIT IS NOT COMPATIBLE WITH THIS
MODEL.
9. USE N.E.C CLASS 2 WIRE.
SELECTOR SWITCH
DS1 - DS6
LOW VOLTAGE
LOW VOLTAGE FIELD
HIGH VOLTAGE
HIGH VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
RESISTOR
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
EQUIPMENT GROUND
FIELD GROUND
FAULT RECALL
(SEE NOTE 4)
(SEE NOTE 5)
(SEE NOTE 5)
STATUS LED
X3A
X15A
BS2
X5A
X2A
BS1
SEG2
SEG1
DS1
DS2
X7A
X12A
X13A
RX LED
X8A
INDOOR UNIT
PCB
THERMI STO R
(HEAT EXCHANGE R 1,2)
MPU
CPU LED
PRESSURE
SENSOR
EEV
COIL
EEV
M
K1R
K2R
LEARN
PS
TR1
TH1
TB2
Y2
O
TB1
W2
Y1
C
G
W1
R2 1
DEHUM
S
H
A
R
E
D
A
T
A
F
L
A
S
H
W
R
IT
E
R
R
A
M
M
O
N
IT
O
R
ON OFF
OR
GY
RD
YL
BK
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
X1A
TR2
TB3
F1U
TB4
TB5
TB7
COM
DS3
DS4
DS5
DS6
X3A
X15A
BS2
X5A
X2A
BS1
SEG2
SEG1
DS1
DS2
X7A
X12A
X13A
RX LED
X8A
INDOOR UNIT
PCB
THERMI STO R
(HEAT EXCHANGE R 1,2)
MPU
CPU LED
PRESSURE
SENSOR
EEV
COIL
EEV
M
K1R
K2R
LEARN
PS
F2U
TR1
TH1
TB2
Y2
O
TB1
W2
Y1
C
G
W1
R2 1
DEHUM
S
H
A
R
E
D
A
T
A
F
L
A
S
H
W
R
IT
E
R
R
A
M
M
O
N
IT
O
R
ON OFF
INTEGRATION
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
X1A
TH2
TB10
TR2
TB3
F1U
TB4
TB5
TB8
ACC-OUT
TB7
DS3
DS4
DS5
DS6
AUX ALARM
(ALARM)
GR
AUX ALARM
(ALARM)
GR
RELAY IN
(ACC-OUT)
RELAY OUT
(ACC-IN)
GY
BK
THERMOSTAT (SEE NOTE 9)
RD
BK
BK
RD
VAC
BL
TYP E
RD
ON OFF
READ THE INSTRUCTIONS
GR
RD
BL
PU
YL
RD
ACC-IN
TB6
K3R
PK
FPL FEMALE PLUG
MPL
MALE PLUG
DIP SWITCH (OFF)
COLOR CODES:
BL
RD
YL
OR
BK
GY
BR
GR
PU
WH
PK
- BLUE
- RED
- YELLOW
- ORANGE
- BLACK
- GREY
- BROWN
- GREEN
- PURPLE
- WHITE
- PINK