SERVICING
72
Setting Function
1 OFF No Use
2 OFF No Use
3 OFF No Use
4 OFF No Use
5 OFF No Use
6 OFF No Use
7 OFF No Use
8 OFF No Use
9 OFF Heater Kit Selection in Emergency Mode
10 OFF Heater Kit Selection in Emergency Mode
11 OFF Heater Kit Selection in Emergency Mode
12 OFF Heater Kit Selection in Emergency Mode
13 ON Allow in Emergency Mode (Fan Emergency Mode)
14 OFF Allow in Emergency Mode (Fan Emergency Mode)
15 ON EEV Enable**
16 OFF No Use
17 ON Emergency EEV Opening
18 OFF Emergency EEV Opening
19 OFF EEV Emergency Mode**
20 OFF No Use
21 OFF Emergency mode (Cooling & Heating Emergency Mode)
22 OFF Emergency mode (Cooling & Heating Emergency Mode)
23 OFF No Use
24 OFF No Use
1 ON CT Communication Enable*
2 ON CT Communication Enable*
1 ON Cooling Emergency mode*
2 ON Cooling Emergency mode*
ID DS-5
ID DS-6
OD DS-1
OD DS-2
Switch #
Dipswitch
Default Factory Settings
ID DS-1
ID DS-2
ID DS-3
ID DS-4
* Must be set at factory setting to operate the normal mode.
** Must be set at factory setting in indoor unit with EEV. It's prohibited to change setting.