EasyManua.ls Logo

Amana M8 User Manual

Amana M8
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
5151 San Felipe Suite 500 • Houston, TX 77056
www.goodmanmfg.com • www.amana-hac.com
© 2011 - 2015 Goodman Manufacturing Company, L.P.
ATTENTION INSTALLING PERSONNEL
As a professional installer, you have an obligation to know the
product better than the customer. This includes all safety pre-
cautions and related items.
Prior to actual installation, thoroughly familiarize yourself with
this Instruction Manual. Pay special attention to all safety warn-
ings. Often during installation or repair, it is possible to place
yourself in a position which is more hazardous than when the
unit is in operation.
Remember, it is your responsibility to install the product safely
and to know it well enough to be able to instruct a customer in
its safe use.
Safety is a matter of common sense...a matter of thinking before
acting. Most dealers have a list of specific, good safety
practices...follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conflict between existing practices and the content of
this manual, the precautions listed here take precedence.
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION
NOTE: Please contact your distributor or our website listed
below for the applicable Specification Sheet referred to in this
manual.
Installer: Affix all manuals
adjacent to the unit.
These furnaces comply with requirements embodied in
the American National Standard / National Standard of
Canada ANSI Z21.47·CSA-2.3 Gas Fired Central Furnaces.
IO-446C
11/2015
INSTALLATION INSTRUCTIONS FOR
*M(H,S)8 / GD(H,S)8 / GHS8 / GME8
ADS(H,S)8 / AMEH8 G
AS FURNACE
(CATEGORY I )
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.
TABLE OF CONTENTS
Safety Considerations......................................................3
Additional Safety Considerations ....................................4
Shipping Inspection ..........................................................4
Electrostatic Discharge (ESD) Precautions.......................5
To The Installer..................................................................5
PRODUCT APPLICATION............................................................5
LOCATION REQUIREMENTS AND CONSIDERATIONS ..................6
Clearances and Accessibility ...........................................7
Installation Positions.......................................................7
Horizontal Installation .....................................................7
Furnace Suspension..........................................................8
Existing Furnace Removal.................................................8
Thermostat Location .........................................................8
COMBUSTION AND VENTILATION AIR REQUIREMENTS .............8
CATEGORY I VENTING (VERTICAL VENTING) ..............................9
EXTERIOR MASONRY CHIMNEYS
(CATEGORY I FURNACES ONLY) .........................................10
Checklist Summary..........................................................10
Check 1 - Proper chimney termination ..........................11
Check 2 - Any solid or liquid fuel appliances
vented into this chimney channel ..............................11
Check 3 - Chimney Crown Condition...............................12
Check 4 - Debris in Cleanout...........................................12
Check 5 - Liner Condition. ...............................................12
Check 6 - Dilution Air. .....................................................12
Check 7 - Complete the Installation................................12
Fix 1 - Liner Termination .................................................13
Fix 2 -Change Venting Arrangements ..............................13
Fix 3 - Rebuild the Crown ................................................13
Fix 4 - Relining ................................................................13
ELECTRICAL CONNECTIONS.....................................................14
Wiring Harness...............................................................14
115 Volt Line Connections ..............................................14
Fossil Fuel Applications .................................................14
Junction Box Relocation .................................................14
24 Volt Thermostat Wiring .............................................15
GME8 & AMEH8 Furnaces
with 2-Stage Condenser Field Wiring ........................15
Setting the Heat Anticipator ............................................16
115 Volt Line Connection of Accessories........................16
Electronic Air Cleaner .....................................................16
24 Vac Humidifier ...........................................................16
GAS SUPPLY AND PIPING ........................................................16
High Altitude Derate ........................................................17
Propane Gas Conversion ................................................17
Gas Piping Connections..................................................17
Upflow Installations.......................................................18
Counterflow Installations ..............................................18
Gas Piping Checks...........................................................18
Propane Gas Tanks and Piping .......................................19

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Amana M8 and is the answer not in the manual?

Amana M8 Specifications

General IconGeneral
AFUE Rating80%
StagesSingle Stage
EfficiencyUp to 80%
Heating Capacity40, 000 to 120, 000 BTU/h
Warranty10-Year Parts

Summary

SAFETY CONSIDERATIONS

SHIPPING INSPECTION

Check for external damage on shipping containers and secure contents.

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

Steps to prevent damage to electronic components from static discharge.

PRODUCT APPLICATION

LOCATION REQUIREMENTS AND CONSIDERATIONS

INSTALLATION POSITIONS

Guidelines for placing the furnace vertically or horizontally.

CLEARANCES AND ACCESSIBILITY

Recommended unobstructed clearances for servicing and accessibility.

CATEGORY I VENTING (VERTICAL VENTING)

Venting - Furnace Installed in Horizontal Position

Procedure for horizontally venting the furnace through an exterior side wall.

CHECKLIST SUMMARY

CHECK 1 - PROPER CHIMNEY TERMINATION

Ensures the chimney extends correctly above the roof and from obstructions.

CHECK 5 - LINER CONDITION

Verifies the chimney liner is correctly installed, sized, and in good condition.

FIX 4 - RELINING

ELECTRICAL CONNECTIONS

115 VOLT LINE CONNECTIONS

Instructions for connecting the furnace to the 115-volt power supply.

JUNCTION BOX RELOCATION

Steps to relocate the junction box for electrical connections.

24 VOLT THERMOSTAT WIRING

GAS SUPPLY AND PIPING

INLET GAS SUPPLY PRESSURE

Specifies required inlet gas pressure for natural and propane gas.

GAS PIPING CONNECTIONS

Instructions for making gas piping connections to the furnace.

START-UP PROCEDURE AND ADJUSTMENT

FURNACE START-UP

Detailed procedure for starting the furnace for the first time.

GAS SUPPLY PRESSURE MEASUREMENT

MODELS USING SINGLE STAGE GAS VALVES

Procedure for measuring gas supply pressure on single-stage valve models.

GAS MANIFOLD PRESSURE MEASUREMENT AND ADJUSTMENT

OPERATIONAL CHECKS

CHECKING DUCT STATIC

Procedure to measure and determine total external duct static pressure.

SAFETY CIRCUIT DESCRIPTION

INTEGRATED CONTROL MODULE

Description of the electronic module controlling furnace operations and safety.

PRIMARY LIMIT

Monitors heat exchanger compartment temperatures for overheating.

TROUBLESHOOTING

DIAGNOSTIC CHART

Chart to determine unit operational problems using diagnostic LED codes.

RESETTING FROM LOCKOUT

Methods to reset the furnace after it enters a lockout state.

MAINTENANCE

ANNUAL INSPECTION

Recommends annual inspection by a qualified installer for system health.

BLOWER PERFORMANCE DATA (*M(H,S)/8)

*(M, D, H)S8 / ADSS8 WIRING DIAGRAM