EasyManua.ls Logo

American Standard Selectronic 606B.X10 - INSTALL VACUUM BREAKER AND FLUSH CONNECTIONS

American Standard Selectronic 606B.X10
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
M965643 Rev. 1.6 (11/16)
4
INSTALL VACUUM BREAKER AND
FLUSH CONNECTIONS; Fig. 6
1. Place the SPUD FLANGE (1) over the spud on the Fixture.
Fig. 6.
2. Place FRICTION WASHER (3) and SEAL WASHER (4) inside
SPUD COUPLING NUT (2) and thread onto Spud. Do not
tighten fully. Fig. 6.
3. Remove the ELBOW COUPLING NUTS (6, 6a) from the
CHROME ELBOW (5). Make sure there are a RUBBER (7), &
FIBER GASKET (8) in each. Fig. 6a.
4. With the ange end up, slide the FIBER GASKET (8) and
ELBOW COUPLING NUT (6) onto the VERTICAL OUTLET
PIPE (9). Place the RUBBER GASKET (7) onto the ange.
Now connect the ELBOW COUPLING NUT (6) to the
CHROME ELBOW (5) and tighten fully.
5. Insert the VERTICAL OUTLET PIPE (9) with CHROME ELBOW
(5) assembly into the SPUD COUPLING NUT (2) and push it
down. Do not tighten fully. Fig. 6a.
Note: Cutting the VERTICAL OUTLET PIPE (10) may be nec-
essary for the CHROME ELBOW (5) center line to line up with
opening in the wall.
6. Measure and cut the HORIZONTAL OUTLET PIPE (10) to length
required. Fig. 6b.
Important: Make sure that there is a minimum of 1-1/4" for
engagement with coupling when making your measurement.
7. With the ange end toward the BRASS ELBOW (11) slide the
FIBER GASKET (12) and ELBOW COUPLING NUT (13) onto the
HORIZONTAL OUTLET PIPE (10). Place the RUBBER GASKET
(14) between the ange and the BRASS ELBOW (11) and fully
tighten. Fig. 6b.
8. From behind the wall, insert the assembled BRASS ELBOW and
HORIZONTAL OUTLET PIPE (11, 10) through the hole in the
wall. Install WALL ESCUTCHEON (15) onto the HORIZONTAL
OUTLET PIPE (10). Slide the ELBOW COUPLING NUT (6a)
and TAPERED RUBBER WASHER (7a) onto the HORIZONTAL
OUTLET PIPE (10). Push the HORIZONTAL OUTLET PIPE (10)
into the CHROME
ELBOW (5). Tighten ELBOW COUPLING NUT (6a) but not fully.
Fig. 6b.
9. For back spud installations: Follow steps #1 and #2 to install
the spud coupling kit. Push the HORIZONTAL OUTLET PIPE
(10) into the spud connection on the back of the xture. Do not
tighten fully. Fig. 6b.
10. All installations: If required, cut VACUUM BREAKER PIPE
(17), leave a minimum of 1-1/4" (32mm) of pipe to ensure
engagement with compression coupling. Assemble the ELBOW
COUPLING NUT (13a) and TAPERED RUBBER WASHER
(14a) onto the VACUUM BREAKER PIPE (17). Install VACUUM
BREAKER PIPE (17) into BRASS ELBOW (11) and hand
tighten ELBOW COUPLING NUT (13a). Fig. 6c.
Note: If cutting VACUUM BREAKER PIPE (17) to size, note
that Critical Line (C/L) on Vacuum Breaker must typically
be 6" (152mm) above xture. Consult Code for details.
Fig. 6
Fig. 6a
Fig. 6b
Fig. 6c
1
2
3
4
3/4" TOP SPUD
8
8a
6a
7
7a
5
6
9
FLANGE END UP
10
BACK SPUD
INSTALLATION
TOP SPUD
INSTALLATION
TOP SPUD
INSTALLATION
2
BACK SPUD
INSTALLATION
11
TAPERED SIDE UP
TAPERED
SIDE UP
13a
17
19
14a
13
15
12
11
6a
7a
5
FLANGE END
10
14

Related product manuals