EasyManua.ls Logo

Ametek Sorensen XG 100-8.5 User Manual

Ametek Sorensen XG 100-8.5
399 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PROGRAMMABLE POWER
M370430-01 Rev F www.programmablepower.com
XG Family Programmable DC
Power Supply
Operating Manual
(firmware v 2.0 and higher)
670 Watts – 1700 Watts
Half Rack
Full Rack
6 V to 600 V Models:
6-110
6-220
6-220
8-100
8-187.5
8-200
12-70
12.5-120
12-140
20-42
20-76
20-84
33-25
30-50
33-50
40-21
40-38
40-42
60-14
60-25
60-28
80-10.5
80-19
80-21
100-8.5
100-15
100-17
150-5.6
150-10
150-11.2
300-2.8
300-5
300-5.6
600-1.4
600-2.6
600-2.8

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen XG 100-8.5 and is the answer not in the manual?

Ametek Sorensen XG 100-8.5 Specifications

General IconGeneral
BrandAmetek
ModelSorensen XG 100-8.5
CategoryPower Supply
LanguageEnglish

Summary

Warranty and Product Return

2 Installation

3 Local Operation

Auto Start and Protection Features

Covers auto start modes and general protection features like foldback and OVP.

Alarms and Errors Management

Explains how alarms are triggered, displayed, and cleared, including error handling.

Protection Mechanisms (Foldback, OVP, UVP, OTP)

Details the configuration and usage of various protection mechanisms like Foldback and OVP.

4 Analog Programming (APG) and ISOL

APG Voltage and Current Control Methods

Explains voltage and current control using external voltage or resistive sources.

5 Remote Operation

SCPI Status Reporting Overview

Introduces SCPI standard status reporting mechanisms and registers.

Status Registers (Byte, Operation, Standard Event)

Details the Status Byte, Operation, and Standard Event Status Registers.

Questionable, Voltage, Temperature Status Registers

Explains the function and bits of Questionable, Voltage, and Temperature status registers.

SCPI Register Commands

Lists SCPI commands for managing Operation, Shutdown, and Protection status registers.

Protection Mechanism Configuration (Masking, Latching)

Details how to configure protection masks and alarm output latching.

Auto Sequence Programming Features

Covers storing, loading, running, and managing auto sequence programs.

Analog Programming Level Configuration

Details setting the input range for analog programming levels.

Remote Programming Interface Selection

Explains how to select the remote source for analog programming.

6 Communications Options

LAN Connection and Configuration Methods

Explains different LAN connection types and configuration steps.

LAN Parameter Settings

IP Address Configuration

Instructions for setting static or DHCP IP addresses for LAN connectivity.

Static IP Address Configuration Steps

Provides step-by-step guides for setting static IP addresses via Ethernet, USB, Serial.

Communication Software Setup (NI MAX)

Guides on installing and configuring National Instruments MAX for serial communication.

7 Calibration and Troubleshooting

Output Voltage and Current Calibration

Details procedures for calibrating output voltage and current, including gain and offset.

Analog Programming Calibration Procedures

Covers calibration for non-isolated and isolated analog programming modes.

User Diagnostics and Troubleshooting Guide

Provides guidance for operator-level troubleshooting of common issues.

Related product manuals