PROGRAMMABLE POWER
M370430-01 Rev F www.programmablepower.com
XG Family Programmable DC
Power Supply
Operating Manual
(firmware v 2.0 and higher)
670 Watts 1700 Watts
Half Rack
Full Rack
6 V to 600 V Models:
6-110
6-220
6-220
8-100
8-187.5
8-200
12-70
12.5-120
12-140
20-42
20-76
20-84
33-25
30-50
33-50
40-21
40-38
40-42
60-14
60-25
60-28
80-10.5
80-19
80-21
100-8.5
100-15
100-17
150-5.6
150-10
150-11.2
300-2.8
300-5
300-5.6
600-1.4
600-2.6
600-2.8

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen XG 300-2.8 and is the answer not in the manual?

Ametek Sorensen XG 300-2.8 Specifications

General IconGeneral
ModelXG 300-2.8
TypeProgrammable DC Power Supply
Output Voltage0-300 V
Output Current0-2.8 A
Power Rating840 W
Temperature Coefficient100 ppm/°C
Frequency47-63 Hz
Operating Temperature0 to 50 °C
Storage Temperature-40 to 70 °C
Dimensions133 mm x 214 mm x 439 mm
Weight8.2 kg
Efficiency85%
CoolingForced Air

Summary

Warranty Terms and Return Procedures

PRODUCT RETURN PROCEDURE

Details the process for requesting a Return Material Authorization (RMA) number for product repair.

Important Safety Instructions

High Energy and High Voltage Warning

Caution regarding high energy levels and potentially lethal voltages at output terminals.

Fire Hazard Warning

Warning to operate the power supply in a non-flammable environment and avoid unauthorized modifications.

Limitations on Use Warning

Specifies that the power supply is not intended for life support or medical equipment.

Battery Charger Caution

Advises on using appropriate fuses or circuit breakers when using the supply for battery charging.

Standard Warnings and Precautions

Installation Guide

Basic Setup Procedure

Summarizes the essential steps for installing the power supply.

Step 3: Connecting AC Input Power

Details on safely connecting the AC input power to the power supply unit.

Step 5: Performing Functional Tests

Procedures for performing functional checks, including power-on and mode operations.

Voltage and Current Mode Operation Checks

Steps to verify the correct operation of voltage and current modes.

Step 7: Connecting Remote Sensing

Instructions for connecting remote sensing wires to shift regulation point to the load.

Local Operation of the Power Supply

Configuring Settings from the Front Panel

Details on using the 9-position mode control and rotary adjust/enter for front panel configuration.

Alarms and Errors

Information on conditions that cause alarms and the alarm order of precedence.

Using Over Voltage Protection (OVP)

Explanation of the OVP circuit and its function in protecting the load.

Using Under Voltage Protection (UVP)

Explanation of the UVP circuit and its function in creating a voltage window.

Over Current Protection (OCP)

Details on the OCP alarm, which is firmware-configurable via SCPI interface.

Using Over Temperature Protection Lock (OTP)

Explanation of OTP lock for protecting against overheating and its available modes.

Resetting the Power Supply

Procedure for performing a soft reset to clear parameters to factory default values.

Using Multiple Power Supplies

Guidance on operating power supplies in series for increased voltage or parallel for increased current.

Configuring Multiple Supplies for Series Operation

Instructions for connecting up to two power supplies in series to increase output voltage.

Analog Programming (APG) and Isolated Analog Programming (ISOL)

Analog Programming (APG) of Output Voltage and Output Current

Explains how to control output voltage and current using analog input sources.

Voltage-Controlled Voltage APG Setup

Procedure for activating and deactivating APG voltage mode using an external voltage source.

Voltage-Controlled Current APG Setup

Procedure for activating and deactivating APG current mode using an external voltage source.

Resistive-Controlled Voltage APG Setup

Procedure for activating and deactivating APG voltage mode using an external resistor.

Resistive-Controlled Current APG Setup

Procedure for activating and deactivating APG current mode using an external resistor source.

Voltage-Controlled Voltage ISOL Setup

Procedure for activating and deactivating ISOL voltage mode using an external voltage source.

Voltage-Controlled Current ISOL Setup

Procedure for activating and deactivating ISOL current mode using an external voltage source.

Resistive-Controlled Voltage ISOL Setup

Procedure for activating and deactivating ISOL voltage mode using an external resistor.

Resistive-Controlled Current ISOL Setup

Procedure for activating and deactivating ISOL current mode using an external resistor.

Remote Operation of the Power Supply

Configuring Remote Control Using RS-232

Steps to configure remote control via RS-232 interface.

Configuring Remote Control Using RS-485

Steps to configure remote control via RS-485 interface, including cable details.

Configuring Remote Control using the USB Connector

Instructions for setting up the PC and installing drivers for USB connection.

Selecting a Communication Port

Guide to selecting the appropriate communication port (RS-232, RS-485, USB, GPIB, LAN).

Multiple Power Supply Setup

Configuration steps for master and slave units in a multi-power supply setup.

Selecting the Appropriate Communication Port

Guide to selecting communication ports for remote digital programming and readback.

Status Reporting in SCPI

Overview of SCPI standard status reporting and XG specific reporting framework.

Reset Command

Procedure for performing a device reset to restore known states and default settings.

Locking and Unlocking the Front Panel

Procedure to lock or unlock the front panel to prevent unauthorized changes.

Auto Sequence Programming

Enables execution of programs stored in power supply memory for automated tasks.

Running an Auto Sequence Program

Commands to run, stop, or pause an auto sequence program.

Protection Mask (Enable Alarms)

Allows masking of alarms to prevent SCPI detection, accessible via SCPI command.

Communications Options

SETTING UP LAN/ETHERNET

Procedures for network administrators to configure LAN/Ethernet connections.

LOCAL AREA NETWORK (LAN) OPTION

Details on programmable functions over LAN (Ethernet) interface.

AMETEK LXI Discovery Browser

Software tool to locate LXI compliant devices on the network.

Using the AMETEK LXI Discovery Browser

How to use the LXI Discovery Browser to locate and launch the power supply's web interface.

AMETEK ENETTEST UTILITY

Utility application for sending SCPI commands and receiving responses over Ethernet.

Using the AMETEK Ethernet Test Utility

Instructions on setting Host and Port fields for the Ethernet Test Utility.

SETTING LAN PARAMETERS

Methods to set required LAN information: Ethernet, Serial/USB, or Web Interface.

Calibration and Troubleshooting Guide

Calibrating the Output Voltage

Procedure for gain and offset calibration of the output voltage.

Calibrating the Output Current

Procedure for gain and offset calibration of the output current.

Over Voltage Protection Calibration

Procedure for calibrating the over voltage protection system.

Calibrating the Input Voltage APG Signal

Calibration steps for the input voltage APG signal gain and offset.

Calibrating the Input Current APG Signal

Calibration steps for the input current APG signal gain and offset.

Troubleshooting for Operators

Table listing common symptoms, checks, and corrections for operator troubleshooting.

APPENDIX A SCPI Command Reference

SCPI Command Summary

Provides tables summarizing SCPI commands for various functions.

APPENDIX B Error Messages

APPENDIX C Specifications

Electrical Specifications for XG Family, 850 W

Provides detailed electrical specifications for XG 850 Watt models.

Electrical Specifications for XG Family, 1500 W

Provides detailed electrical specifications for XG 1500 Watt models.

Electrical Specifications for XG Family, 1700 W

Provides detailed electrical specifications for XG 1700 Watt models.

APPENDIX D Rack Mount Options and Installation Instructions

APPENDIX E Lantronix Procedures for MEA Option

Terminal Configuration

Parameters for setting up terminal programs like HyperTerminal for serial communication.

Troubleshooting for XG 850W Model with ENET and/or RS-485 Communication

Troubleshooting procedures for combined ENET-RS-485 communication and ENET setup.

Related product manuals