APPENDIX A   
SCPI Command Reference   
Table A-4  SCPI Commands for Calibration (Continued) 
Calibrate the 
Voltage 
controlled Non 
Isolated 
Current APG 
feature 
[:]CALibration[<channel>]:OUTPut :ANAL
og:CURRent 
Calibrate the current analog 
programming system. 
? | <NR1> | <nothing 
for interactive mode> 
Calibrate the 
Voltage 
controlled 
Isolated 
Current APG 
feature 
[:]CALibration[<channel>]:OUTPut :ANAL
og:CURRent:ISOLated 
Calibrates the current analog 
programming system. 
? | <NR1> | <nothing 
for interactive mode> 
Calibrate the 
Resistive 
controlled Non 
Isolated 
Voltage APG 
feature 
[:]CALibration[<channel>]:OUTPut :ANAL
og[:VOLTage]:RESistive 
Calibrate the Resistive 
controlled voltage analog 
programming system. 
? | <NR1> | <nothing 
for interactive mode> 
Calibrate the 
Resistive 
controlled 
Isolated 
Voltage APG 
feature 
[:]CALibration[<channel>]:OUTPut :ANAL
og[:VOLTage] :RESistive:ISOLated 
Calibrates the Resistive 
controlled voltage analog 
programming system. 
? | <NR1> | <nothing 
for interactive mode> 
Calibrate the 
Resistive 
controlled Non 
Isolated 
Current APG 
feature 
[:]CALibration[<channel>]:OUTPut :ANAL
og:CURRent:RESistive 
Calibrate the Resistive 
controlled current analog 
programming system. 
? | <NR1> | <nothing 
for interactive mode>