M370430-01 Rev F A-15
A
APPENDIX A
SCPI Command Reference
Table A-1 IEEE 488.2 Commands (Continued)
Display All
SCPI
Command
Headers
*HELP?
Display all the SCPI
command headers available
on this device.
Yes
Identification
Query
*IDN? [:]SYSTem[<channel>]:IDENtify?
Query device identification
string.
Yes
Operation
Complete
Command
*OPC
Operation Complete
Command
N/A
Query
Operation
Complete
Command
*OPC?
Operation Complete Query
Yes
Recall
*RCL OR
[:]SYSTem[<channel>]:RECall
<setting_location>
Recall a User Memory
Setting. See *SAV below.
<Setting Index (1
5)>
N/A
Reset
*RST [:]SYSTem[<channel>]:RESet
Resets all values to default
state (excluding calibration
data).
N/A
Save User
Settings
*SAV
[:]SYSTem[<channel>]:SAVE
<setting location>
Save a User Memory Setting.
N/A
Query Service
Request
Enable
*SRE?
[:]STATus[<channel>]:SREQuest:ENABle?
Service Request Enable
Query
Yes
Service
Request
Enable
*SRE
[:]STATus[<channel>]:SREQuest:ENABle
<status-enable>
Service Request Enable
Command
<Enable Flags(0
255)>
N/A
Read Status
Byte
*STB?
[:]STATus[<channel>]:SBYTe[EVENt]?
Read the status byte.
Yes