Local Operation
M370430-01 Rev F 3-39
3
User Setting Memory Locations
There are three user setting memory locations available for storing
frequently used configurations. These user setting memory locations
help to facilitate multiple users of an XG power supply who have
different setups or when multiple loads are used that have different
requirements. Table 3-8 lists the values that are stored in each user
setting memory location.
Table 3-8 User Accessible Saved/Recalled Settings Voltage Setpoint
Voltage Setpoint
Current Setpoint
Voltage Output Protection
Current Output Protection
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Autostart OUTPUT ENABLE Main
Autostart OUTPUT ENABLE Aux
Foldback Mode
Foldback Delay
Shutdown Logic
Voltage Analog Programming (VAP) Mode
Voltage Analog Programming (VAP) Level
Current Analog Programming (CAP) Mode
Current Analog Programming (CAP) Level
Current Sharing Mode
Alarm Latches
Front Panel Timeout