Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-20 M370430-01 Rev F
Isolated Analog Programming Mode (ISOL)
See “Rear Panel Connectors on 850 Watt Models” on page 1-7 Rear
Panel Connectors on 1500 and 1700 Watt Models” on page 1-9 for more
details about connections.
AUX Output and Isolated Analog Programming (ISOL) Connector
The AUX Output and Isolated Analog Programming (ISOL) Connector
is a 15-pin female DSUB connector. See Figure 4-10. All pins on this
connector are electrically isolated from the output of the power supply.
The AUX Output and ISOL Connector provides access to the following
functions:
Function
XG1500 and 1700
XG850
Auxiliary +5 V and +15 V outputs
standard
standard
OUTPUT ENABLE Aux
standard
standard
Power On Status (output)
optional
standard
SDShutdown (input)
standard
standard
Interlock
standard
standard
ISOL programming and monitoring
optional
standard
Figure 4-10 AUX Output and ISOL Connector Pinout