Local Operation
M370430-01 Rev F 3-15
3
4. Set the desired current value using the rotary Adjust/Enter
control.
5. Once the desired value has been set, press the rotary
Adjust/Enter control to commit the setting.
Important: The control circuits have been designed so that output current can
be set up to 105% over the model-rated maximum values. The power supply
will operate within these extended ranges, but full performance to specification
is not guaranteed.
The SCPI command (s) for these instructions are:
[[:]SOURce[<channel>]]:CURRent[:LEVEl][:IMMediate]
[:AMPLitude]