8.0.1 Ge ne ral in for ma ti on
• Ob ser ve the sa fe ty in for ma ti on
• Only qual i fied and authorised per sons may carry out re -
pair work
• In case of faults, the op er at ing and main te nance in struc -
tions must be re ferred to for cor rect op er a tion and main -
te nance.
• If the cause of the fault can not be lo cated or rem e died, an
authorised Ammann Ser vice Cen tre should be con tacted.
• Al ways first check the most li ke ly cau ses (fu ses, LEDs,
etc.)
60
8. Trou bles hoo ting
8.0.2 Fault tab le
Pos si ble cau se Re me dy Re marks
En gi ne do es not start
Fu el de fi cien cy
Fu el val ve clo sed
No fu el supp ly at car bu ret tor
En gi ne switch set to «OFF»
Re fill fu el
Set fu el val ve to «OPEN»
Check
Set en gi ne switch to «ON»
No spark at spark plug (HONDA) Check Re mo ve plug con nec tor. Cle an ba se of spark
plug.
Fit spark plug in plug con nec tor.
Hold si de elec tro de of spark plug against any
point of the en gi ne, pull out the star ter ca ble
and check for spark in for ma ti on.
No spark ð re pla ce plug
Spark ð fit plug and at tempt to start en gi ne
If the en gi ne still do es not start, con tact an aut ho ri sed Am mann or Hon da Ser vi ce Centre.
Re du ced en gi ne per for man ce
Air fil ter clog ged Cle an air fil ter; re pla ce if ne ces sa ry
En gi ne runs, ma chi ne do es not mo ve for ward
In suf fi cient V-belt ten si on
V-belt bro ken
Cen tri fu gal clutch li ning worn
Re ten ti on V-belt
Re pla ce V-belt
Re pla ce li nings and springs Am mann-Ser vi ce