6.8 Air fil ter
Clean in take port (1).
Open cover (2).
Open re tain ing clips (3) and re move cover (4).
Care fully re move fil ter el e ment (5) from fil ter hous ing (6).
Clean fil ter cover (4) and hous ing (6).
Check fil ter el e ment (5) for cracks or other dam age by hold ing
against the light or us ing a lamp.
Beat the se cu rity el e ment eas ily out.
Blow out fil ter el e ment (5) with dry com pressed air (max. 5
bar) from in side to the out side.
Note num ber of clean ing cy cles on the fil ter el e ment.
Care re fit fil ter el e ment (5).
Fit cover (4) and se cure with clips (3).
Close cover (2).
6. En gine main te nance
67
Change the fil ter el e ment:
if the fil ter el e ment or seal ing ring is dam aged
af ter clean ing six times
if sooty de pos its are pres ent
if moist or oily de pos its are pres ent
if en gine per for mance re duces or
if the ex haust gas changes col our
min i mum once a year
Never op er ate the en gine with out air fil ter el e ment.
The fil ter car tridge and the se cu rity el e ment not
wash out.
The se cu rity el e ment not blow out with com -
pressed air.
Danger
Wear safety gog gles – risk of eye in ju ries!