7.2.4 Hy drau lic oil change
Com pletely re move the cover (1).
Screw off the fil ter cap (2).
Re move the re turn-line fil ter el e ment (3).
Re move the plate (4).
Open the drain plug (5) and let the oil out.
Screw the drain plug (5) in and use a new seal (7).
Add fresh oil (see the lu bri ca tion plan for the oil quan tity and
type).
Re place the re turn-line fil ter el e ment (3) and ven ti la tion fil ter (6).
Screw on the fil ter cap (2) and use a new gas ket, if nec es sary.
Af ter a short test run, check the oil level again and add, if nec -
es sary.
In stall the cover.