EasyManua.ls Logo

Amprobe AMP-330 - Resistance Specifications; Capacitance Specifications; Diode Test Specifications; DC Microamp Specifications

Amprobe AMP-330
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Resistance
Range Accuracy
600.0 Ω, 6.000 kΩ, 60.00 kΩ ± (1.0 % + 5 LSD)
Open Circuit Voltage: 1.0VDC typical
Capacitance
Range Accuracy
1)
200.0 μF, 2500 μF ± (2.0 % + 4 LSD)
1)Accuracy with film capacitor or better
Diode
Range Accuracy
2.000 V ± (1.5 % + 5 LSD)
Test Current: 0.3mA typically
Open Circuit Voltage: < 3.5VDC typically
DC μA
Range Accuracy Burden Voltage
200.0 μA, 2000 μA ± (1.0 % + 5 LSD) 3.5 mV/μA
Temperature
Range Accuracy
-40.0 °C to -10.0 °C ±(1% + 1.5 °C)
> -10 °C to 99.9 °C ±(1% + 0.8 °C)
100 °C to 400 °C ±(1% + 1 °C)
-40.0 °F to 14.0 °F ±(1% + 3.0 °F)
> 14.0 °F to 99.9 °F ±(1% + 1.5 °F)
100 °F to 752 °F ±(1% + 2 °F)
K-type thermocouple accuracy tolerances not included
Precise Low Current AC
Range Accuracy
1) 2) 3)
0.00 A to 20.00 A ± (1.5 % + 5 LSD) @ 40 Hz to 100 Hz
± (2.0 % + 5 LSD) @ 100 Hz to 400 Hz
>20.00 A to 60.00 A ± (3.0 % + 5 LSD) @ 40 Hz to 100 Hz
± (3.0 % + 5 LSD) @ 100 Hz to 400 Hz
1) Induced error from adjacent current-carrying conductor: < 0.02 A/A
2) Specified with relative zero
mode applied to offset the non-zero
residual readings, if any.
3) Add 10 LSD to the specified accuracy @ < 4 A
www.GlobalTestSupply.com