EasyManua.ls Logo

Amtech Axpert-Eazy AMT-090-4 - User Manual

Default Icon
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
NOTICE
1. Read this manual thoroughly before using the Axpert-Eazy, and store in a safe place for reference.
2. Make sure that this manual is delivered to the final user.
200 V System, 11 kW (15 Hp) ~ 90 kW (125 Hp)
400 V System, 22 kW (30 Hp) ~ 1550 kW (2075 Hp)
500 V System, 30 kW (40 Hp) ~ 1550 kW (2075 Hp)
600 V System, 30 kW (40 Hp) ~ 1800 kW (2415 Hp)
Instruction Manual
Axpert-Eazy Series
AMTECH
IMAE-01, Rev. 1.20
JUL 2017
AMTECH

Table of Contents

Questions and Answers

  • L
    Lee WilsonSep 5, 2025
    What causes Output Current Unbalance in Amtech Axpert-Eazy AMT-090-4 DC Drives?
    • M
      morrisjudySep 5, 2025
      Output Current Unbalance in Amtech DC Drives can stem from various factors. Ensure that the parameters are set properly. Abnormal setting of V/F, Torque Boost, Acceleration time and Speed search function related parameters and current limit may result in output current unbalance. Increase the acceleration time (A201 / A203). If fault occurs during deceleration, increase the deceleration time (A202 / A204). Abnormal setting of DC braking parameters can result in unbalance current fault during deceleration. Reduce the dc braking start frequency (A306) and dc braking time (A308) settings if used.
  • J
    Jennifer FreemanNov 19, 2025
    What to do if Amtech Axpert-Eazy AMT-090-4 DC Drives show an Over Current Fault?
    • A
      allenjustinNov 19, 2025
      If your Amtech DC Drive displays an Over Current Fault, several issues could be the cause. First, the power module(s) in the main circuit might be damaged, so switch off the power supply and check them. Second, there may be a loose or improper connection of the current sensor cable, or a short in the cable. In this case, switch off the power supply, remove the cable, and inspect it for proper crimping on both sides. Reinsert the cable securely. If the issue persists, replace the cable. Third, the current sensor itself may have failed, so switch off the power supply, remove the current sensor, and check. If no fault is observed, replace the damaged current sensor. Fourth, the fault may originate from the Driver Board. Switch off the power supply and remove the FRC (in case of wire interface...
  • P
    padillaangelSep 18, 2025
    What to do if Amtech Axpert-Eazy AMT-090-4 DC Drives show an EEPROM Fault?
    • D
      Daniel FritzSep 18, 2025
      If your Amtech DC Drive is showing an EEPROM Fault, it means the data received from the EEPROM is incorrect or out of range. On fault reset, default values will be stored in the EEPROM. If the fault occurs again after power recycling, replace PCA-2014A.
  • J
    Jay LevineSep 16, 2025
    How to troubleshoot Auto Tuning Fault in Amtech Axpert-Eazy AMT-090-4 DC Drives?
    • C
      Cassidy BlevinsSep 16, 2025
      If you encounter an Auto Tuning Fault in your Amtech DC Drive, it means the auto-tuning process has failed. The motor parameter setting value may be incorrect, so set the correct motor parameter. Ensure that the motor is directly connected to the inverter, removing any additional components like output chokes during auto-tuning.
  • J
    Jeanette SmithSep 14, 2025
    What to do if Amtech DC Drives show an External Fault?
    • S
      Sarah WilsonSep 14, 2025
      If your Amtech DC Drive displays an External Fault, the signal for the external fault is present at the PSI. Check and correct it. If the signal is not present, remove the selection of the external fault with the help of Mode-C parameters. There may be a problem in PCA-2014A, so remove the control board PCA-2014A.
  • I
    Isaac SanchezSep 12, 2025
    What does Reference Missing mean on Amtech Axpert-Eazy AMT-090-4 DC Drives?
    • C
      Carlos MunozSep 12, 2025
      If your Amtech DC Drive shows Reference Missing, the analog current input reference (4-20 mA) to the unit is below 3 mA. Check the voltage level at FSI terminal of PCA-2014A.
  • M
    michael99Sep 12, 2025
    What causes Under Current Fault in Amtech Axpert-Eazy AMT-090-4?
    • D
      David MillerSep 12, 2025
      An Under Current Fault in Amtech DC Drives may occur if the Under Current Limit B304 is set too low. Disable the feature by setting 0% in B304.
  • M
    Michael KingSep 9, 2025
    What to do if my Amtech DC Drives have Charging Fault?
    • H
      Hannah HernandezSep 9, 2025
      If your Amtech DC Drive displays a Charging Fault, the DC bus voltage didn’t reach the predefined voltage level within 5 seconds after power up. The soft charge resistor may be open. One or more phases may have failed. DC bus voltage feedback may be missing. Ensure proper connection of DC bus voltage feedback at J9.
  • N
    nelsonmeghanSep 7, 2025
    What to do if Amtech Axpert-Eazy AMT-090-4 DC Drives show an Output Phase Loss?
    • G
      Gary WatsonSep 7, 2025
      If your Amtech DC Drive indicates an Output Phase Loss, it could be due to a single phasing of the motor, so disconnect and check the motor. It can also happen if one or more output cables are open or loosely connected, so check the output connections and correct it.
  • D
    douglas06Aug 22, 2025
    What causes Amtech DC Drives to have an Over Voltage Fault?
    • J
      Jessica GordonAug 22, 2025
      An Over Voltage Fault in Amtech DC Drives can occur if the power supply voltage rises above specified limits (785 VDC for 400 V series, 965 VDC for 500 V series, or 1160 VDC for 600 V series). Reduce the voltage to stay within the correct range. It can also happen if the speed is fluctuating.

Summary

PREFACE

Precautions For Safety

Essential safety guidelines to prevent hazards during operation, installation, and maintenance.

CHAPTER-2 INSTALLATION AND WIRING

2-1 Installation environment

Guidelines for selecting an appropriate installation location and ensuring proper ventilation for the AC Drive.

2-2 Precautions for power supply and motor wiring

Critical safety instructions for connecting power supply and motor wiring to prevent electric shock and fires.

CHAPTER-4 TEST OPERATION AND ADJUSTMENT

4-1 Preparation before turning power ON

Essential checks and preparations before applying input power to the AC DRIVE unit.

4-3 Automatic tuning & adjustment

Procedure for automatic tuning to measure and adjust motor constants for optimal performance.

CHAPTER-5 CONTROL INPUT; OUTPUT TERMINALS

CHAPTER-6 PARAMETER SETTINGS & FUNCTIONS

CHAPTER-8 MAINTENANCE, INSPECTION AND PART REPLACEMENT

8-1 Inspection items

Periodic inspection guidelines and daily checks to ensure the AC DRIVE operates reliably and safely.

CHAPTER-11 SERIAL COMMUNICATION SET-UP

CHAPTER-12 UL INSTRUCTIONS

CHAPTER-13 CE MARKING

Amtech Axpert-Eazy AMT-090-4 Specifications

General IconGeneral
BrandAmtech
ModelAxpert-Eazy AMT-090-4
CategoryDC Drives
LanguageEnglish