Do you have a question about the AND EJ-200 and is the answer not in the manual?
Readability | 0.01 g |
---|---|
Repeatability (σ) | 0.01 g |
Linearity | ±0.02 g |
Display | LCD |
Calibration | External Calibration |
Units of Measurement | g, oz, ozt, dwt, ct |
Auto-off | Yes |
Details the items to check when unpacking the balance, including main units and accessories.
Guides users on placing the weighing pan, leveling the balance, and initial calibration.
Explains how to connect the AC adapter or install dry-cell batteries for operation.
Mentions the availability of an optional breeze break accessory.
Provides instructions on how to stack balances safely when not in use.
Details how to switch the balance power on and off, including the auto-power off function.
Explains the function and settings of the balance's LCD backlight.
Lists and explains various weighing units and their conversion to grams.
Instructions on how to select the desired weighing unit using the UNITS key.
Guides through the fundamental weighing process, including taring and reading values.
Explains how to use the balance for counting items by unit weight.
Details how to use the balance to display weight as a percentage of a reference.
Provides a step-by-step example for setting up the comparator function.
Details the process of calibrating the balance using a calibration weight.
Explains how to adjust the balance for gravity variations in different locations.
Explains the role of each key and how to navigate the balance's functions.
Guides users on how to access and navigate the balance's function setting menu.
Provides an example of setting specific functions like auto power-off and ACAI.
Instructions on how to select and store frequently used weighing units.
A list of all available functions, their parameters, and descriptions.
Details the EJ-02 USB interface for computer connectivity and data transfer.
Explains the EJ-03 RS-232C serial interface for printer or PC connection.
Describes the underhook option for weighing large objects or measuring density.
Details the EJ-11 breeze break option, used to minimize air disturbance.
Information about the EJ-12 carrying case for balance portability.
Explains the EJ-13 kit for determining the density (specific gravity) of samples.
Guides on how to set the ID number for Good Laboratory Practice (GLP) reporting.
Provides examples of GLP data output formats for calibration reports.
Details how to perform a calibration test to confirm weighing accuracy.
Important notes and precautions regarding balance maintenance and cleaning.
Lists and explains various error codes displayed by the balance and their meanings.
Detailed technical specifications including capacity, display, and linearity for each model.
Provides capacity and minimum display details for various alternative weighing units.
Lists optional accessories available for the EJ series balances.
Provides dimensional drawings and measurements for the EJ series balances.