2021/01 Rev. 0.4
OptiMeOptiMe
13 / 38
Display Possible cause Solution
continuation...
E25
FLOW METER
ERROR
Attention; Flow meter
error does not always
mean that the flow
meter is defect.
When the software
starts the espresso pump
the flow meter must
produce impulses.
Why the flow meter
impulses are not made
or do not arrive must be
investigated.
The espresso pump KW2 is
activated and takes water from the
air break, but the flow meter FL1
does not register water flow.
Check if the flow meter FL1 connector is
mounted correctly.
Check that the connector is not wet or
oxidized. See picture on the left.
Check after which recipe the error
occurs and check if one of below
mentioned dispensing valves are
involved with the problem: DV1 brewer,
DV2 mixer, DV4 hot water recipe.
Replace if necessary.
1007352*(5x)
DV1
DV4
DV3
DV2
DV5
HOT WATER
TO COFFEE BREWER
TO INSTANT MIXER
TO STEAM BOILER
FROM BOILER
E26
TEMPERATURE HOT
WATER BOILER
TOO LOW
Temperature sensor in hot water
boiler measures a boiler temperature
below 0 °C.
Boiler and/or NTC sensor is below
0°C. Let the machine warm up to room
temperature.