Problem / Possible cause Modication
Milk temperature to low.
Reducing the milk pump speed does not have
effect.
Insufficient steam supply to the milk venturi.
During 24/7 use of the machine, sealing of the steam supply
valve can develop a deformation leading to a reduced flow
resulting in the above mentioned problem.
From production week 50/2020 (s / n: 2VD61344) the
valve is mounted in a new position and is then no longer on
top of the steam boiler.
Art. No. 1010013 Replacement set steam valve
Explanation of the pictures on the right:
1. Location of the seal in the steam valve
2. Deformed and good sealing
3. Original steam valve position
4. New steam valve position
Select the link below or scan the QR code
Build-in instructions modification kit.
Modification!