Chapter 4 OTDR Commands
4-16
4.4.7 SENSe:LIVCheck:Command
Syntax: SENSe:LIVCheck<wsp><value>
Parameters: <value>
Boolean value
1 or on = Live fiber check is ON.
0 or off = Live fiber check is OFF.
Description: Sets live fiber check option ON or OFF.
Example: sens:livc ON<END>
Response: NONE
Errors:
(–200, "std_execGen, Test is Active")
(–104, "std_wrongParamType, Data Type Error")
4.4.8 SENSe:FIBer:IOR Command
Syntax: SENSe:FIBer:IOR<wsp><value>
Parameters: <value>
Floating point format
Range: 1.400000 – 1.699999
Description: Sets index of refraction. This value will be used for the next test.
Example: sens:fib:ior 1.45
Response: None
Errors: (–200, "std_execGen, Test is Active")
(–224, "std_illegalParmValue, Invalid Parameter Value")
4.4.9 SENSe:FIBer:IOR? Command
Syntax: SENSe:FIBer:IOR?
Parameters: None
Description: Queries index of refraction.
Example: sens:fib:ior? --- 1.450000<END>
Response: Possible response is value in range:
1.400000 – 1.699999
Errors: None