Set Baud Rate Control Byte #197 (C5h)
Description: Set baud rate for this session. An invalid setting returns the baud rate to 9600.
Bytes to Follow: 1 byte
1) Baud Rate Index
00h = 9600 baud
01h = 19200 baud
02h = 38400 baud
03h = 56000 baud
04h = 115200 baud
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid baud rate index
238 (EEh) Time Out Error
Set Language Control Byte #198 (C6h)
Description: Set the Site Master display language.
Bytes to Follow: 1 byte
1) Language Index
00h = English
01h = French
02h = German
03h = Spanish
04h = Chinese
05h = Japanese
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid language index
238 (EEh) Time Out Error
Query Time Control Byte #208 (D0h)
Description: Queries the Site Master for the current time in ASCII format.
Bytes to Follow: 0 bytes
Site Master Returns: 8 bytes (HH:MM:SS)
1) Hour (higher byte)
2) Hour (lower byte)
3) :
4) Minute (higher byte)
5) Minute (lower byte)
6) :
7) Second (higher byte)
8) Second (lower byte)