3. Press the night reduction button again to
end the night reduction function.
– When the humidity level is less that
57%, the compressor stops and the
fan stops 30 seconds later.
– When the humidity level is higher
than 63%, the fan starts and the
compressor starts 3 seconds later.
– Fan speed and set target humidity
cannot be adjusted in night
reduction mode.
Timer
When the dehumidier is running, the timer
function is used to set the time for automatic
power-o. When the dehumidier is switched
o, the timer function is used to set the time
for start.
1. Press the timer button to activate the
timer function.
2. The adjustable time is from 0 to 12 hours
in steps of 1 hour. The set time is increased
by 1 hour each time the button is pressed.
The corresponding value is shown on the
display.
3. Set the value to 00 to deactivate the
timer function. The status light goes o.
When the timer function is activated the
status light goes on during the set time.
When the set time has expired the status
light goes o automatically.
Setting the target humidity
Press the button for setting target air
humidity for 3 seconds to display the ambient
temperature.
1. Press the button for setting target air
humidity to show the ambient humidity
on the display.
2. Press again to set the target humidity.
The target humidity can be set from 30
to 80% in steps of 5%. 3 seconds after
the setting is nished, the set value is
conrmed and the setting mode ends.
The display returns to show ambient
humidity. The target humidity cannot be
set in continuous dehumidication mode.
Fan speed
Press the button for fan speed to switch
between high and low fan speed. The
corresponding status light goes on.
It is not possible to change fan speed during
continuous dehumidication, night reduction
or defrosting.
Childlock
Press for 3 seconds to activate/deactivate the
childlock.
MAINTENANCE
OPERATING TEMPERATURE
• The dehumidier can be used in rooms
with a temperature from 5 to 35°C.
• At higher or lower ambient temperatures,
the product will automatically switch o.
• At ambient temperatures from 5 to 16°C
the compressor is automatically defrosted
when necessary. The compressor is
switched o during defrosting and the fan
works.
EMPTYING THE WATER TANK
The water tank can be emptied in two ways as
follows.
• Manual emptying of the water tank
• Continuous emptying of the water tank
NOTE:
Do not use chemical detergents.
Manual emptying of the water
tank
The dehumidier stops automatically when the
built-in water tank is full. It starts again when
the water tank is emptied and replaced correctly.
1. When the water tank is full an audio
prompt is given, and the status light for
full water tank goes on.