EasyManua.ls Logo

Anyload T15C-R - Keypad

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 | ANYLOAD NPS Series Pallet Jack Scale Operator’s Guide (V1906) T15E v2 series indicator
4.6 Keypad
POWER KEY / ZERO KEY
This key is the POWER key. It is also the ZERO key. Pressing
and holding this key will turn on or off the device. During
weighing mode and when the weigh pan is empty (free
of load) and the display is not showing zero, pressing this
“ZERO” key will return the scale to zero. (The weight shall be
zero at 2% of Max. capacity)
TARE KEY / “RIGHT” KEY
This key is the TARE key. It is also use as “RIGHT“ arrow key
during the function and calibration mode. The tare function
will not operate during the following conditions:
1. At weighing mode, if the display is showing negative after
removing the container from the weigh pan; or if the weight
reading is still lesser than zero.
2. The tare weight value is more than the full scale’s capacity.
UNIT KEY / LOAD KEY
This key is the UNIT key. Use this key to switch between kg
and lb units of measurement. This is also the LOAD key when
the scale is in function or calibration mode.
FUNCTION KEY
This key is the FUNCTION key. Use this key to switch the scale
to the following functions: Simple counting, Check weighing,
Accumulation and Animal weighing/Hold.
PRINT KEY / CONFIRM KEY
This key is the PRINT key. Use this key to print data when the
printer is connected. This is also the “CONFIRMkey when the
scale is in function or calibration mode.

Related product manuals