EasyManua.ls Logo

Anywave MHPTV - Page 28

Anywave MHPTV
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHPTV TX Quick Start Guide
MHPTV-QSG-DOC-V1.1, 12/05/2018 Page 28 of 37
8-PA 208VAC, Three-Phase AC Distribution Wiring
A1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
1L1 3L2 5L3
2T1 4T2 6T3
A2
-
DC24 V
+
AC208V
L N Gnd
Schneider
C120H C100
1 2 3 4 5
L1 L2 L3 Gnd
KDY-20-4P
Gnd
Gnd
Gnd
Gnd
Gnd
UK35
AC
24v/50w
F16-371/24VD
SIEMENS
3RT50461BB40
UK50
PE
Set-top fan
Spare5
Spare4
Spare3
Spare2
Spare1
Exciter one
Exciter two
Controller
Load
Amp1
Amp2
Amp3
Amp4
Amp5
Amp6
Amp7
Amp8
Properly connect the four wires to the terminal block as shown in the above
diagram, taking care to notice which terminal is connected to the chassis Ground in
your system. Be sure to connect the GND terminal properly and other three
connections as L1, L2, and L3.