EasyManua.ls Logo

APC 2200VA - User Manual

APC 2200VA
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
990-1054A, 08/01
User’s Manual
English
APC Smart-UPS
®
2200VA/3000VA 3U Rack Mount
Uninterruptible Power Supply
230VAC/120VAC
Question and Answer IconNeed help?

Do you have a question about the APC 2200VA and is the answer not in the manual?

Summary

Safety Information

Handling Safety

Guidelines for safely lifting and handling the UPS unit due to its weight.

Life Support Application Policy

APC's policy regarding the use of its products in life support applications.

Electrical and De-energizing Safety

Electrical Safety

Safety precautions related to electrical connections and grounding.

De-energizing Safety

Procedures for safely de-energizing the UPS unit and its components.

Battery Safety and Recycling

Battery Safety

Safety warnings and precautions when handling batteries.

Battery Replacement and Recycling

Information on how to replace batteries and options for recycling.

Installation

Unpacking and Positioning

Instructions for inspecting, unpacking, and selecting a suitable location for the UPS.

Installing the Smart-UPS

Basic steps for installing the UPS unit into an equipment rack.

Installation Steps

Installing Mounting Rails

Detailed instructions for installing the mounting rails within the equipment rack.

Removing the Battery Module

Procedure for safely removing the heavy battery module from the UPS.

Rack Mounting and Battery Reinstallation

Mounting the UPS in the Rack

Steps for physically mounting the UPS unit into the rack using rails and screws.

Reinstalling the Battery Module

Instructions for reinserting the battery module back into the UPS unit.

Connections and Power Up

Connecting Battery and Front Bezel

Steps to connect the battery module and attach the front bezel of the UPS.

Connecting Power and Equipment

Guidance on connecting the UPS to AC power and peripheral equipment.

Turning On and Accessories

Turning On the UPS

Instructions on how to properly power on the UPS unit.

Accessories

Information about optional accessories and software for the UPS.

Operation

Front Panel Indicators and Controls

Overview of the front panel controls and indicator lights on the UPS.

Powering the UPS On and Off

Explanation of how to power the UPS on and off using the front panel buttons.

Load Indicators

Description of the five-LED display indicating the connected equipment's load percentage.

Operation Details

Self-Test Procedures

Details on automatic and manual self-testing procedures for the UPS.

Utility Power Monitoring

How the UPS monitors and displays utility power status and voltage.

Battery and Shutdown Operation

Battery Power Operation

Information on UPS operation using battery power and battery charge indicators.

Shutdown Mode

Explanation of how the UPS can be commanded to shut down via software or accessories.

Operation Indicators and Breakers

Low Battery Warning

Configuration of the low battery warning beeps and intervals.

Site Wiring Fault Indicator

Information about the indicator for incorrectly wired AC power outlets.

Circuit Breakers

Details on the input and output circuit breakers for the UPS.

On-Battery Runtime

On-Battery Operation

How the UPS operates when utility power fails and switches to battery power.

Determining On-Battery Run Time

Guidance on estimating the UPS run time based on load and battery capacity.

User Configuration Items

Automatic Self-Test Settings

Setting the interval for the UPS to perform an automatic self-test.

UPS Identification and Battery Replacement Date

Assigning a UPS ID and recording the battery replacement date.

Shutdown and Warning Settings

Configuring minimum capacity, low battery warning, and shutdown delays.

Sensitivity and Turn-on Delay

Adjusting UPS sensitivity and synchronized turn-on delay settings.

Voltage Transfer Points

High Transfer Point

Setting the high voltage threshold for transferring to battery power.

Low Transfer Point

Setting the low voltage threshold for transferring to battery power.

Storage and Maintenance

Storage Conditions and Extended Storage

Recommended conditions for storing the UPS and charging during extended non-use.

Battery Replacement Procedure

Detailed steps for replacing the UPS battery module and front bezel.

Transporting Your Smart-UPS

Removing UPS from Rack and Front Bezel

Procedures for safely removing the UPS unit from a rack and detaching the front bezel.

Troubleshooting

Power and Operation Issues

Common causes and solutions for UPS power, turn-on, turn-off, and operation problems.

Operational Anomalies

Troubleshooting UPS beeps, short backup time, and flashing panel indicators.

Troubleshooting Indicator and Alarm Issues

Indicator and Alarm Issues

Diagnosing and resolving UPS issues indicated by lights, alarms, and beeping.

Contact, Regulatory, and Warranty Information

Service and Support

Steps for obtaining service and contacting APC customer support.

Regulatory Approvals and Interference

Listing of regulatory approvals and information on radio frequency interference.

Conformity and Warranty

Declaration of Conformity

Statement declaring the equipment's conformity with relevant standards and directives.

Limited Warranty

Summary of the product's limited warranty terms and conditions.

Summary

Safety Information

Handling Safety

Guidelines for safely lifting and handling the UPS unit due to its weight.

Life Support Application Policy

APC's policy regarding the use of its products in life support applications.

Electrical and De-energizing Safety

Electrical Safety

Safety precautions related to electrical connections and grounding.

De-energizing Safety

Procedures for safely de-energizing the UPS unit and its components.

Battery Safety and Recycling

Battery Safety

Safety warnings and precautions when handling batteries.

Battery Replacement and Recycling

Information on how to replace batteries and options for recycling.

Installation

Unpacking and Positioning

Instructions for inspecting, unpacking, and selecting a suitable location for the UPS.

Installing the Smart-UPS

Basic steps for installing the UPS unit into an equipment rack.

Installation Steps

Installing Mounting Rails

Detailed instructions for installing the mounting rails within the equipment rack.

Removing the Battery Module

Procedure for safely removing the heavy battery module from the UPS.

Rack Mounting and Battery Reinstallation

Mounting the UPS in the Rack

Steps for physically mounting the UPS unit into the rack using rails and screws.

Reinstalling the Battery Module

Instructions for reinserting the battery module back into the UPS unit.

Connections and Power Up

Connecting Battery and Front Bezel

Steps to connect the battery module and attach the front bezel of the UPS.

Connecting Power and Equipment

Guidance on connecting the UPS to AC power and peripheral equipment.

Turning On and Accessories

Turning On the UPS

Instructions on how to properly power on the UPS unit.

Accessories

Information about optional accessories and software for the UPS.

Operation

Front Panel Indicators and Controls

Overview of the front panel controls and indicator lights on the UPS.

Powering the UPS On and Off

Explanation of how to power the UPS on and off using the front panel buttons.

Load Indicators

Description of the five-LED display indicating the connected equipment's load percentage.

Operation Details

Self-Test Procedures

Details on automatic and manual self-testing procedures for the UPS.

Utility Power Monitoring

How the UPS monitors and displays utility power status and voltage.

Battery and Shutdown Operation

Battery Power Operation

Information on UPS operation using battery power and battery charge indicators.

Shutdown Mode

Explanation of how the UPS can be commanded to shut down via software or accessories.

Operation Indicators and Breakers

Low Battery Warning

Configuration of the low battery warning beeps and intervals.

Site Wiring Fault Indicator

Information about the indicator for incorrectly wired AC power outlets.

Circuit Breakers

Details on the input and output circuit breakers for the UPS.

On-Battery Runtime

On-Battery Operation

How the UPS operates when utility power fails and switches to battery power.

Determining On-Battery Run Time

Guidance on estimating the UPS run time based on load and battery capacity.

User Configuration Items

Automatic Self-Test Settings

Setting the interval for the UPS to perform an automatic self-test.

UPS Identification and Battery Replacement Date

Assigning a UPS ID and recording the battery replacement date.

Shutdown and Warning Settings

Configuring minimum capacity, low battery warning, and shutdown delays.

Sensitivity and Turn-on Delay

Adjusting UPS sensitivity and synchronized turn-on delay settings.

Voltage Transfer Points

High Transfer Point

Setting the high voltage threshold for transferring to battery power.

Low Transfer Point

Setting the low voltage threshold for transferring to battery power.

Storage and Maintenance

Storage Conditions and Extended Storage

Recommended conditions for storing the UPS and charging during extended non-use.

Battery Replacement Procedure

Detailed steps for replacing the UPS battery module and front bezel.

Transporting Your Smart-UPS

Removing UPS from Rack and Front Bezel

Procedures for safely removing the UPS unit from a rack and detaching the front bezel.

Troubleshooting

Power and Operation Issues

Common causes and solutions for UPS power, turn-on, turn-off, and operation problems.

Operational Anomalies

Troubleshooting UPS beeps, short backup time, and flashing panel indicators.

Troubleshooting Indicator and Alarm Issues

Indicator and Alarm Issues

Diagnosing and resolving UPS issues indicated by lights, alarms, and beeping.

Contact, Regulatory, and Warranty Information

Service and Support

Steps for obtaining service and contacting APC customer support.

Regulatory Approvals and Interference

Listing of regulatory approvals and information on radio frequency interference.

Conformity and Warranty

Declaration of Conformity

Statement declaring the equipment's conformity with relevant standards and directives.

Limited Warranty

Summary of the product's limited warranty terms and conditions.

APC 2200VA Specifications

General IconGeneral
TopologyLine Interactive
Form FactorTower
Nominal Output Voltage120V
Nominal Input Voltage120V
Capacity2200 VA
Output ConnectionsNEMA 5-15R
Battery TypeLead-Acid
Frequency50/60 Hz
Interface PortsUSB