APEC ROES-PH75 - Troubleshooting: Water Flow Issues; No Water or Sluggish Flow

APEC ROES-PH75
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
1) No Water at Dispensing Faucet
- Water supply is off —> Turn on the water supply, or open Needle Valve ( turn needle handle
counter colockwise)
- Tank’s valve is closed —> Turn tank valve to an “Open” position
- Output line is crimped —> Remove crimp
- Incorrect installation —> See Fig.11. Verify all line connections.
- Tank defective, no pre-charge pressure —> Set tank pre-charge to 5-7 psi.
- ASO connection Error —> See Fig. 16A and Fig. 16B to reconnect ASO to the correct connection.
The ASO valve has 4 lines connected to it, 2 Whites and 2 Clears. C1 is labeled IN and C2 is labeled
OUT on the valve. C3 and C4 are connected to the ends with the 4 screws. Please confirm connections:
• Stage 3 Carbon: White tubing (point B) is connected to C1 (IN) fig.16A
• Membrane: White tubing (point D) is connected to C2 (OUT) fig.16A
• Check Valve: Clear tubing (point E) is connected to C3 fig.16B
• 5th stage Tee inlet: Clear tubing (point F) is connected to C4 fig.16B
Fig. 16A
Back View
Fig. 16B
Front View