GB
29
Regulator Owner’s Manual
............................................................................................
After The Dive
NOTE: Rinse your regulator completely in fresh water before
depressurising it, and thoroughly dry the first stage and cylinder valve.
This will help to prevent any contaminants from entering the regulator
when it is removed from the cylinder.
Removing the Regulator from the Cylinder Valve
(Yoke Connector)
1. Shut off the cylinder air supply by turning the cylinder valve hand-
wheel clockwise until it stops.
2. While observing the submersible pressure gauge, depress the purge
button of the second stage. When the gauge reads zero and airflow
cannot be heard from the second stage, release the purge button.
3. Turn the yoke screw anti-clockwise to loosen and remove the first
stage from the cylinder valve.
4. Dry the dust cap with a clean towel, or with low pressure air.
5. Place the dust cap over the first stage inlet fitting and seal it securely
in place by tightening down the yoke screw.
Removing the Regulator from the Cylinder Valve
(DIN Connector)
1. Turn off the cylinder air supply by turning the cylinder valve hand-wheel
clockwise until it stops.
2. While observing the submersible pressure gauge, depress the purge
button of the second stage. When the gauge reads zero and airflow
cannot be heard from the second stage, release the purge button.
3. Turn the first stage handwheel anti-clockwise to loosen and remove the
first stage from the cylinder valve.
4. Blow out any water inside the protector cap or wipe it out with a soft
cloth, and wipe the threads of the first stage connector clean and dry.
Install the cap over the threads of the first stage connector.