SX610 pH Pen Tester Kit User Manual
1. Brief Introduction
Thank you for purchasing APERA INSTRUMENTS SX610 pH Pen Tester. This product is featured with
reliable and accurate measuring performance with a single-button operation in a slim body, ideal for
measuring pH in general water solution applications such as hydroponics, greenhouse, aquaculture,
aquarium, water treatment, pools& spas, cooling towers, beverage making, education, environmental
monitoring, body fluid (e.g. urine, saliva). The pH probe is replaceable and suitable for test tube measuring
and other small-volume sample testing.
2. Specifications
1) Range: 0 to 14.0 pH; 32 to 140°F (0 to 60°C)
2) Resolution: 0.1 pH; 0.1°C
3) Accuracy: ± 0.1 pH ±1 digit; ±1°C
4) Automatic temperature compensation: 32 to 140°F (0 to 60°C)
5) Automatic calibration: 1-point calibration (pH 7.0)
6) Power: CR2032 Cell Batteries
7) Dimension and Weight: 148*29*14mm/49g
8) Waterproof rating: IP57
3. Instructions
1) Calibration: Rinse the probe in distilled water and shake off excess water. Immerse the probe in
the standard buffer solution pH7.00. Stir for a few seconds and wait for the reading to stabilize.
Then press the CAL button for about two seconds until CAL appears on the screen. When the
calibration value 7.0 flashes, the calibration will finish after several seconds, and the meter will
return to measurement mode and the icon will appear on the screen.
2) Measurement: Rinse the probe in distilled water and shake off excess water. Immerse the probe
in your sample solution. Stir the probe for a few seconds and wait for the reading to stabilize, then
record the measurement.
3) After measurement, rinse the probe with distilled water, shake off excess water, and put the
protection cap back on.
4) Storage: Always leave a bit 3M KCL storage solution in the probe cap when storing the meter as it
will optimize the performance and maximize the life of the pH probe.
5) Change temperature unit: When meter is turned off, hold the CAL button until the meter reboots
and then the temperature unit will be switched (˚C–˚F)
4. Notes
1) Calibrate the pH pen at least once a month.
2) To ensure the accuracy, make sure the pH standard buffer is fresh and clean. The small bottle of

Other manuals for Apera Instruments SX610

Question and Answer IconNeed help?

Do you have a question about the Apera Instruments SX610 and is the answer not in the manual?

Apera Instruments SX610 Specifications

General IconGeneral
BrandApera Instruments
ModelSX610
CategoryMeasuring Instruments
LanguageEnglish

Summary

Brief Introduction

Product Specifications

pH and Temperature Range

Specifies the operating range for pH measurement and temperature.

Measurement Resolution

Details the smallest increments for pH and temperature readings.

Measurement Accuracy

Defines the precision of pH and temperature measurements.

Automatic Temperature Compensation (ATC)

Specifies the temperature range for ATC functionality.

Automatic Calibration Feature

Highlights the device's 1-point auto-calibration capability.

Power Source

Identifies the battery type used for powering the device.

Physical Dimensions and Weight

Provides the physical size and weight of the pH pen tester.

Waterproof Rating

Indicates the device's protection against dust and water immersion.

Operating Instructions

pH Pen Calibration Procedure

Step-by-step guide for calibrating the pH pen tester.

Performing pH Measurements

Instructions for taking accurate pH readings with the pen tester.

Post-Measurement Care

Steps to take after completing a pH measurement.

Proper Storage Guidelines

Recommendations for storing the pH pen to maintain probe life.

Changing Temperature Units

How to switch between Celsius and Fahrenheit units.

Important Notes and Maintenance

Calibration Frequency

Recommendation to calibrate the pH pen monthly.

Buffer Solution Quality

Ensuring accuracy by using fresh and clean pH standard buffer.

Probe Cleaning and Maintenance

Guidelines for cleaning and maintaining the pH probe for reliable tests.

Electrode Service Life and Replacement

Information on electrode lifespan and when to replace it.

Auto Power Off Feature

Details the device's automatic shutdown after inactivity.

Battery Replacement Indicator

Indicates when the device's batteries need to be replaced.

Storage Medium Restrictions

Prohibits storing the probe in distilled, RO, or deionized water.

Temperature Limits for Testing

Specifies maximum temperature for sample testing for accuracy.

Warranty Information

Product Warranty Coverage

Details the two-year warranty for defects and probe's six-month warranty.

Exclusions from Warranty

Lists conditions and damages not covered by the product warranty.

Related product manuals