12.4 Digital Output Signal
Pin No.
Terminal name Signal name Description
4 READY Ready signal
It turns on, when automatic operation is ready.
6 RUNNING Running signal
It turns on during automatic operation.
8 END
Operation end
signal
It turns on when automatic operation ends.
(ON time approx. 100ms)
10 ACK ACK output
It outputs the timing of axis moving at slide soldering. It turns
ON, after the time that is set on STEP 4 ACK of WK setting..
(ON time approx. 100ms)
12 SOLDER ERROR
Solder error
signal
It outputs at solder shortage or solder clogged.
It automatically returns, when new solder wire is replaced at
solder shortage.
Remove clogged solder and input RESET signal at solder
shortage.
14
IRON UNIT
ERROR
Iron unit error
signal
It turns on at normal state.
Temperature error: it turns off, when the temperature exceeds
temperature alarm range set on the system parameter. The
display turns in orange color. The error is automatically released
after the temperature is recovered.
Iron unit U/D: It turns off, when iron unit up/ down sensor does not
work. Input RESET signal after error cause are solved.
22 COUNTER OUT External output 1
This output is for iron shot counter. It turns on at the end of the
cycle excluding cleaning.
(ON time approx. 100ms)
38
0V 0V COM
The 0V COM is common to both Internal and External power
supply.
40
* It also outputs when Type of system parameter is set to ROB.
* Refer to “13. Soldering Operation” about the timing and condition of output.